NORRISTOWN, PA —
OSHA Inspection: FARGO ASSEMBLY OF PA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FARGO ASSEMBLY OF PA, INC. in 800 WEST WASHINGTON STREET, NORRISTOWN, PA 19401 (NAICS 332618). OSHA activity number 339029928.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FARGO ASSEMBLY OF PA, INC.
- Site address
- 800 WEST WASHINGTON STREET
- City
- NORRISTOWN
- State
- PA
- ZIP
- 19401
- Mailing
- PO BOX 550, NORRISTOWN, PA 19401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 110
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C06 I C
- Issued
- Aug 7, 2013
- Abate by
- Aug 22, 2013
- Penalty
- Initial $3,400 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. a) Fargo Assembly of PA, Inc. - On or about April 29, 2013, the employer had not conducted an annual review between the inspector and each authorized employee.
Recent events (2)
- — I (S) $2550
- — Z (S) $3400
1910.147 D04 I
- Issued
- Aug 7, 2013
- Abate by
- Aug 22, 2013
- Penalty
- Initial $3,400 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. a) Fargo Assembly of PA, Inc. - On or about April 29, 2013, an AMP Incorporated brand wire termination press machine using energy sources of electric and pneumatic did not have Lockout or tag-out devices affixed while maintenance was being performed.
Recent events (2)
- — I (S) $2550
- — Z (S) $3400
1910.305 B01 II
- Issued
- Aug 7, 2013
- Penalty
- Initial $2,890 · Current $2,168 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Fargo Assembly of PA, Inc. - On or about April 29, 2013, an unused knock out opening in a 220 Volt circuit breaker panel box identified as CB-9 was not effectively closed: b) Fargo Assembly of PA, Inc. - On or about April 29, 2013, an unused knock out opening in a 220 Volt circuit breaker panel box identified as CB-10 was not effectively closed: c) Fargo Assembly of PA, Inc. - On or about April 29, 2013, unused openings on the cover plate of a metal switch fixture was not effectively closed: d) Fargo Assembly of PA, Inc. - On or about April 29, 2013, unused openings on the cover plate of a metal switch fixture was not effectively closed: e) Fargo Assembly of PA, Inc. - On or about April 29, 2013, unused openings on the cover plate of a metal switch fixture was not effectively closed:
Recent events (2)
- — I (S) $2167.5
- — Z (S) $2890
1910.305 G02 II
- Issued
- Aug 7, 2013
- Abate by
- Aug 22, 2013
- Penalty
- Initial $3,400 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a) Fargo Assembly of PA, Inc. - On or about April 29, 2013, an AMP Incorporated brand wire termination press machine used by employees utilized flexible cord wiring to a counter device that with two wires spliced.
Recent events (2)
- — I (S) $2550
- — Z (S) $3400
1910.36 G02
- Issued
- Aug 7, 2013
- Abate by
- Aug 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. a) Fargo Assembly of PA, Inc. - On or about April 29, 2013, the employer had portions of an exit access that were not at least 28 inches wide.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1025 D03 I
- Issued
- Aug 7, 2013
- Abate by
- Aug 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(d)(3)(i): The initial determination for lead was not based on employee exposure monitoring results and other relevant considerations listed in 29 CFR 1910.1025(d)(3)(i)(A), (B) and/or (C): a) Fargo Assembly of PA, Inc. - On or about April 29, 2013, the employer did not perform employee exposure monitoring for their initial determination of lead exposure for the operation of a dip soldering machine. b) Fargo Assembly of PA, Inc. - On or about April 29, 2013, the employer did not perform employee exposure monitoring for their initial determination of lead exposure for the operation of three resistance soldering stations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1025 L01 I
- Issued
- Aug 7, 2013
- Abate by
- Aug 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: a) Fargo Assembly of PA, Inc. - On or about April 29, 2013, the employer did not provide information contained in Appendices A and B of 29 CFR 1910.1025 to employees potentially exposure to airborne lead at any level.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Fargo Assembly of PA, INC.
View Fargo Assembly of PA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339029928.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.