CHARLESTON, WV —
OSHA Inspection: FAHEY EXTERIORS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FAHEY EXTERIORS LLC in 932 CENTRAL AVE., CHARLESTON, WV 25302 (NAICS 238160). OSHA activity number 339035123.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FAHEY EXTERIORS LLC
- Site address
- 932 CENTRAL AVE.
- City
- CHARLESTON
- State
- WV
- ZIP
- 25302
- Mailing
- 5356 US RT. 60, HUNTINGTON, WV 25705
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.1200 E01
- Issued
- Aug 14, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59) a. Roofing Project at 932 Central Avenue: The employer had not developed or implemented a written hazard communication program for his employees who work with hazardous materials such as but not limited to Geocel 2300 a tripolymer sealant with a warning identifying it as a combustible during cure as determined on 5-1-13. Abatement Certification Required for this Item
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.1200 G08
- Issued
- Aug 14, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: (Construction Reference: 1926.59) a. Roofing Project On Two Story House: The employer did not maintain material safety data sheets on hazardous materials which the employees were exposed such as but not limited to Geocel 2300 Sealant which was labeled a combustible as determined on 5-8-13. Abatement Certification Required for this Item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H
- Issued
- Aug 14, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and -2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced. a. Roofing Project of the 2 Story House: The employer did not provide information or training on all hazardous materials the employees were expose to such as but not limited to the Goecel 2300 Sealant labeled a combustible as determined on 5-1-13. Abatement Certification Required for this Item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.95 A
- Issued
- Aug 14, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a. Roofing Project on Two Story House: The two employees that carried bundles of shingles weighing approximately 70 pounds per bundle from the ground area where the shingles were stacked to the roof were wearing tennis shoes in lieu of a steel toed work boots as determined on 5-1-13. ABATEMENT CERTIFICATION REQUIRED FOR THIS iTEM
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.100 A
- Issued
- Aug 14, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. Roof of Single Story Addition: Employee was not wearing hard hat while working from the 5 on 12 sloped roof of the addition below employees working above from the main roof of the house as determined on 5-1-13. b. Roofing Project of the Two Story House: The employee working as the ground man was not wearing a hard hat while performing various task on the ground which included carrying bundles of shingles from the ground area where the shingles were stacked to the roof while employees were working above as determined on 5-8-13. ABATEMENT CERTIFICATOION NOT REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.102 A01
- Issued
- Aug 14, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a. Roofing Operation of the Rear Addition: An employee was wearing sun glasses in lieu of safety glasses with side shields while operating the Hitachi pneumatic nail gun to install shingles on the 5 on 12 sloped roof as determined on 5-1-013. b. Main Roof of Two Story House: An employee was wearing his safety glasses on top of his head while using a Hitachi pneumatic nail gun to install the shingles on the 6 on 12 sloped roof as observed on 5-1-13.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.501 B13
- Issued
- Aug 14, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Single Story Back Addition: Employee was exposed to a fall of approximately 11 feet while installing singles on the 5 on 12 sloped roof with out any type of fall protection as determined on 5-1-13. b) Main Roof of House: Employees were exposed to falls of approximately 22 feet while walking / working from the 6 on 12 sloped roof performing tasks such as but not limited to installing shingles as observed on 5-1-13.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B21
- Issued
- Aug 14, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(21): Employees were not grasping the ladder with at least one hand when progressing up and/or down the ladder: a. East Side of the House: The employees that carried the bundles of shingles weighing approximately 70 pounds up the Werner fiberglass extension ladder had the bundles on their shoulder with their arm draped over the bundle to stabilize it and did not maintain a 3 point contact with the ladder and therefore could not grasp the ladder with one hand when progressing up the ladder as determined on 5-1-13. ABATEMENT CERTIFICATION rEQUIRED FOR THIS iTEM.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.50 D01
- Issued
- Aug 14, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.50(d)(1): First-aid supplies were not easily accessible when required: a. Roofing Project of the Two Story House: The employer did not have a first aid kit on site for his employees who were performing various tasks on site such as but not limited to carrying shingles, cutting shingles and installing shingles with pneumatic nail guns as determined on 5-1-13. ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Fahey Exteriors LLC
View Fahey Exteriors LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339035123.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.