PEORIA, IL —
OSHA Inspection: AA&L ROOFING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AA&L ROOFING, INC. in 9401 N GALENA RD, PEORIA, IL 61615 (NAICS 238160). OSHA activity number 339035404.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AA&L ROOFING, INC.
- Site address
- 9401 N GALENA RD
- City
- PEORIA
- State
- IL
- ZIP
- 61615
- Mailing
- PO BOX 101, CHILLICOTHE, IL 61523
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B02
- Issued
- Jun 18, 2013
- Abate by
- Jul 15, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): Employees conducting roofing activities were exposed to fall hazards of approximately 13.5 feet from the ground and the employer did not inspect the job site to ensure the hazards were addressed as demonstrated by the lack of fall protection.
Recent events (1)
- — Z (S) $2000
1926.501 B10
- Issued
- Jun 18, 2013
- Abate by
- Jul 15, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: Employees conducting roofing activities were exposed to fall hazards of approximately 13.5 feet from the ground and fall protection was not utilized.
Recent events (1)
- — Z (S) $2000
1926.503 A01
- Issued
- Jun 18, 2013
- Abate by
- Jul 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Employees conducting roofing activities were exposed to fall hazards of approximately 13.5 feet from the ground and were not able to recognize the hazards as demonstrated by the lack of fall protection.
Recent events (1)
- — Z (S) $0
1926.1408 A01
- Issued
- Jun 18, 2013
- Abate by
- Jul 15, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1408(a)(1): The Employer failed to identify the work zone by either demarcating the boundaries or defining the work zone 360 degrees around the equipment. Employees operating a boom truck were exposed to electrical hazards because the employer did not mark or define safe operating areas for the boom to be used so that accidental contact with nearby overhead power lines would not occur.
Recent events (1)
- — Z (S) $2000
1926.1408 A02
- Issued
- Jun 18, 2013
- Abate by
- Jul 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1408(a)(2): The employer did not determine if any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could get closer than 20 feet to a power line. Employees operating a boom truck were exposed to electrical hazards because the employer did not measure or define a safe operating area for the boom to be used so that accidental contact with nearby overhead power lines would not occur.
Recent events (1)
- — Z (S) $0
More inspections at AA&L Roofing, INC.
View AA&L Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339035404.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.