NEW YORK, NY —
OSHA Inspection: V&P ALTITUDE CORP.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of V&P ALTITUDE CORP. in 325 WEST 33RD STREET, NEW YORK, NY 10001 (NAICS 238150). OSHA activity number 339039042.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- V&P ALTITUDE CORP.
- Site address
- 325 WEST 33RD STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10001
- Mailing
- 3709 FORT HAMILTON PARKWAY
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 G01 VII
- Issued
- Sep 17, 2013
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 325 West 33rd Street New York, NY / South East side of the Building - Second Floor On or about March 18-21 2013 a) Employees were installing siding from a tubular welded frame scaffold that was not provided with any fall protection system. The employees were exposed to a potential fall hazard of up to 26 feet to the ground below.
Recent events (3)
- — F (S) $2000
- — C (S) $2800
- — Z (S) $2800
1926.451 B01 I
- Issued
- Sep 17, 2013
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Location: 325 West 33rd Street, NY. / Front Entrance South East side of the Building On or about March 18-21, 2013 a) Employees were installing siding from a tubular welded frame scaffold that was not fully planked. The employees were exposed to a potential fall hazard of up to 26 feet to the ground below. b) Employees were installing windows from a tubular welded mobile scaffold that was not fully planked. The employees were exposed to a potential fall hazard of up to 7 feet to the ground below.
Recent events (3)
- — F (S) $1500
- — C (S) $2800
- — Z (S) $2800
1926.451 C01
- Issued
- Sep 17, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. Location: 325 West 33rd Street New York, NY / South East side of the Building On or about 03/21/13. a) Employees were installing siding from 32 feet high tubular welded frame scaffold that was not restrained from tipping.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.451 E01
- Issued
- Sep 17, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. Location: 325 West 33rd Street New York, NY. / South East side of the Building - Second Floor on or about March 18-21, 2013. a) Employees were working from a 32 feet high tubular welded frame scaffold that did not have means of access. Employees climbed frames and crossbraces to get to work platform.
Recent events (3)
- — F (S) $1500
- — C (S) $2000
- — Z (S) $2000
1926.452 W02
- Issued
- Sep 17, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner: Location: 325 West 33rd Street New York, NY/ Second Floor On or about March 21, 2013 a) Two employees were working on a tubular welded frame mobile scaffold which casters and wheels were not locked to prevent movement of the scaffold.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
More inspections at V&P Altitude Corp.
View V&P Altitude Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 238150)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339039042.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.