MURPHYSBORO, IL —
OSHA Inspection: NORMAN FRED TRUCK SERVICE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORMAN FRED TRUCK SERVICE, INC. in 1248 ENTERPRISE AVE, MURPHYSBORO, IL 62966 (NAICS 811411). OSHA activity number 339039869.
Where did this inspection happen?
- Establishment
- NORMAN FRED TRUCK SERVICE, INC.
- Site address
- 1248 ENTERPRISE AVE
- City
- MURPHYSBORO
- State
- IL
- ZIP
- 62966
- Mailing
- 1248 ENTERPRISE AVE, MURPHYSBORO, IL 62966
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811411
- Employees
- 11
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1120.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) In the Shop Area, north wall, on the electrical panel breaker box, two breakers were missing and no protective blanks had been inserted to cover the inner exposed metal electrical parts.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1120.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Southeast section of the Lawnmower Shop, the 110 volt flexible cord, Safety Kleen tank, was missing its electrical grounding pin in the plug.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Southeast section of the Lawnmower Shop, the 110 volt flexible cord, supplying power to the Safety Kleen tank, was being used as a substitute wiring for fixed permanent wiring in the structure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) A written Hazard Communications program regarding hazardous chemicals had not been developed to inform and train employees to protect them from chemicals hazards. Employees working with hazardous chemicals such as but not limited to motor brake fluid, gasoline, penetrating oil, and Safety Kleen solvent, were exposed to the hazards associated with those products.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical: Material safety data sheets were not kept that would provide information in case of a medical emergency or condition if an employee ingested or contacted chemicals. Employees working with hazardous chemicals such as but not limited to motor brake fluid, gasoline, penetrating oil, and Safety Kleen solvent, were exposed to the hazards associated with those products.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(2)(i): The employer did not provide information to the employees on the requirements of the Hazard Communication Standard 29 CFR 1910.1200: Employees had not been trained regarding the use of hazardous such as but not limited to motor brake fluid, gasoline, penetrating oil, and Safety Kleen solvent. The company did not have Material Safety Data Sheets and a list of chemicals used within the facility.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv): Employees had not been trained regarding methods to detect hazardous chemicals, the physical and health hazards of chemicals, and measures used to protect themselves from hazardous chemicals in the workplace. Chemicals such as but not limited to motor brake fluid, gasoline, penetrating oil, and Safety Kleen solvent were in use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811411)
KENT, WA—2026-04-02
WA317990618 - SUPERIOR CONTENTS LLC
WATSONTOWN, PA—2026-01-20
LANDPRO EQUIPMENT
MURRAY, UT—2025-12-16
HOWE RENTAL & SALES
ONEONTA, NY—2025-11-26
SWANTAK JOSEPH INC
NEW CASTLE, DE—2025-11-24
CAPPELLI PROPERTY SERVICES, LLC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339039869.