OSHA Inspection: NORTHCROSS ROOFING & WATERPROOFING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTHCROSS ROOFING & WATERPROOFING INC. in 301 PLAINFIELD RD., LA GRANGE, IL 60525 (NAICS 238160). OSHA activity number 339051948.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTHCROSS ROOFING & WATERPROOFING INC.
- Site address
- 301 PLAINFIELD RD.
- City
- LA GRANGE
- State
- IL
- ZIP
- 60525
- Mailing
- 1808 BEACH ST., BROADVIEW, IL 60148
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 28
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.502 F01 I
- Issued
- May 23, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1926.502(f)(1)(i): When mechanical equipment is not being used, the warning line shall be erected not less than 6 feet (1.8 m) from the roof edge. a. On or about May 7, 2013 - at the above addressed jobsite, north, south, west and east sides of the roof, warning lines were erected closer than six (6) feet from the roof edge. Employees were thereby exposed to the hazards associated with falls of more than twenty five (25) feet to the ground.
Recent events (2)
- — I (S) $2695
- — Z (S) $5390
1926.502 F02 II
- Issued
- May 23, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain shall be rigged and supported in such a way that its lowest point (including sag) is no less than 34 inches (.9 m) from the walking/working surface and its highest point is no more than 39 inches (1.0 m) from the walking/working surface; a. On or about May 7, 2013 - at the above addressed jobsite, the CAUTION tape warning lines erected on the north, south, west and east sides of the roof were not supported in such way to prevent them from sagging, thereby exposing the employees to the hazards associated with falls of more than twenty five (25) feet to the ground.
Recent events (2)
- — I (S) $1925
- — Z (S) $3850
1926.502 F02 III
- Issued
- May 23, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(2)(iii): After being erected, with the rope, wire, or chain attached, stanchions shall be capable of resisting, without tipping over, a force of at least 16 pounds (71 N) applied horizontally against the stanchion, 30 inches (.8 m) above the walking/working surface, perpendicular to the warning line, and in the direction of the floor, roof, or platform edge; a. On or about May 7, 2013 - at the above addressed jobsite, the CAUTION tape warning lines erected on the north, south, west and east sides of the roof were not supported by stanchions, thereby exposing the employees to the hazards associated with falls of more than twenty five (25) feet to the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 F02 IV
- Issued
- May 23, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(2)(iv): The rope, wire, or chain shall have a minimum tensile strength of 500 pounds (2.22 kN), and after being attached to the stanchions, shall be capable of supporting, without breaking, the loads applied to the stanchions as prescribed in paragraph (f)(2)(iii) of this section; and a. On or about May 7, 2013 - at the above addressed jobsite, the CAUTION tape warning lines erected on the north, south, west and east sides of the roof were not attached to the stanchions and did not meet the minimum tensile strength of 500 pounds, thereby exposing the employees to the hazards associated with falls of more than twenty five (25) feet to the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Northcross Roofing & Waterproofing INC.
View Northcross Roofing & Waterproofing INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339051948.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.