Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: USAF - LOGISTICS READINESS SQUADRON (LRS)

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of USAF - LOGISTICS READINESS SQUADRON (LRS) in BLDG. 4707, DAVIS MONTHAN AFB, AZ 85707 (NAICS 928110). OSHA activity number 339055261.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Usaf - Logistics Readiness Squadron (LRS) — free Get an email when a new federal OSHA severe-injury report for Usaf - Logistics Readiness Squadron (LRS) is published. One employer, no account, unsubscribe in one click.
Site address
BLDG. 4707
City
DAVIS MONTHAN AFB
State
AZ
ZIP
85707
Mailing
5275 E. GRANITE ST., SUITE 1030, DAVIS MONTHAN AFB, AZ 85707
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
50
Ownership type
D

4 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 3, 2013
Abate by
Jul 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.  Dept. of Air Force Davis Monthan AFB - Logistics Readiness Squadron - On or about May 6, 2013 and at times prior thereto Oil Pits with a 71 inch depth to the raised grating and 112 inches above the adjacent floor/ground level were not guarded with a standard railing (or equivalent):  a) Light Duty Shop.  b) Heavy Duty Shop.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Repeat Gravity 10 2 instances 1 exposed
Issued
Jun 3, 2013
Abate by
Jul 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Dept. of Air Force Davis Monthan AFB - Logistics Readiness Squadron - On or about May 6, 2013 and at times prior thereto the Machine Shop: a)  The Toolmaster Milling Machine with Serial Number 5531D5V-110 did not have a guard to protect employees from the point of operation of the rotating cutting head. b)  Jet Head Engine Lathe with Serial Number 907W2582W did not contain a guard to protect employees from the rotating parts and flying metal chips during operation.  The U.S. Air Force was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 467640, notice number 1, item number 4 and was affirmed as a final order on March 18 2013, with respect to a workplace located at Arc Light Blvd. Bldg. 22007, Andersen AFB Yigo GU 96929.  The U.S. Air Force was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 191327, notice number 1, item number 1 and was affirmed as a final order on May 22, 2012, with respect to a workplace located at 730 E. Street, Bldg. 1205, Travis AFB CA 94535.
Recent events (1)
  • — Z (R) $0

1910.215 B09

Repeat Gravity 10 1 instance 2 exposed
Issued
Jun 3, 2013
Abate by
Jun 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  Dept. of Air Force Davis Monthan AFB - Logistics Readiness Squadron - On or about May 6, 2013 and at times prior thereto, The Cincinnati Pedestal Grinders SN 93248 right tongue guard was 5/8 inches from the periphery of the abrasive  wheel.   The U.S. Air Force was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 191646, notice number 1, item number 3 and was affirmed as a final order on August 22, 2013, with respect to a workplace located at 241 V Street Bldg. 878 Travis AFB CA 94353.  The U.S. Air Force was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 461962, notice number 1, item number 1and was affirmed as a final order on December 11, 2012, with respect to a workplace located at Bldg. 18001, Arc Light Blvd. Andersent AFB Yigo GU 96929.  The U.S. Air Force was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 191327, notice number 1, item number 2and was affirmed as a final order on May 22, 2012, with respect to a workplace located at 730 E. Street Bldg. 1205, Travis AFB CA  94535.
Recent events (1)
  • — Z (R) $0

1910.303 G01

Repeat Gravity 5 5 instances 3 exposed
Issued
Jun 3, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  Dept. of Air Force Davis Monthan AFB - Logistics Readiness Squadron - On or about May 6, 2013 and at times prior thereto, the access to and/or working space around electrical equipment was not maintained to permit ready and safe operation and maintenance of the equipment in the Allied Trades Welding Shop.  Welding equipment inhibited access to 5 electrical disconnects boxes in the event of an emergency.   The U.S. Air Force was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 467640, notice number 1, item number 5 and was affirmed as a final order on March 18, 2013, with respect to a workplace located at Anderson AFB, Bldg. 22007, HVAC Arc Light Blvd, Andersen AFB Yigo GU 96929.  The U.S. Air Force was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 191646, notice number 1, item number 5 and was affirmed as a final order on August 22, 2012, with respect to a workplace located at 241 V Street, Bldg. 878, Travis AFB CA 94535.
Recent events (1)
  • — Z (R) $0

View Usaf - Logistics Readiness Squadron (LRS)'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339055261.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.