DAVIS MONTHAN AFB, AZ —
OSHA Inspection: USAF - LOGISTICS READINESS SQUADRON (LRS)
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of USAF - LOGISTICS READINESS SQUADRON (LRS) in 4360 SOUTH PHOENIX STREET BUILDING 4707, DAVIS MONTHAN AFB, AZ 85707 (NAICS 928110). OSHA activity number 345384606.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- USAF - LOGISTICS READINESS SQUADRON (LRS)
- Site address
- 4360 SOUTH PHOENIX STREET BUILDING 4707
- City
- DAVIS MONTHAN AFB
- State
- AZ
- ZIP
- 85707
- Mailing
- 3404 S. FIFTH ST., SUITE 1030, DAVIS MONTHAN AFB, AZ 85707
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 54
- Ownership type
- D
Citations
2 citations on file for this inspection.
1910.253 B04 I
- Issued
- Jul 8, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(i):Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; MACHINE SHOP: Oxygen and acetylene were stored side-by-side without proper protections or barriers, exposing employees to fire hazards.
Recent events (1)
- — Z (S) $0
1910.253 B02 IV
- Issued
- Jul 8, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv):Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: MACHINE SHOP - One oxygen cylinder and one acetylene cylinder were stored without protective caps, exposing employees to struck-by and fire hazards.
Recent events (1)
- — Z (O) $0
More inspections at Usaf - Logistics Readiness Squadron (LRS)
View Usaf - Logistics Readiness Squadron (LRS)'s full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345384606.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.