DELTA, CO —
OSHA Inspection: INDUSTRIAL SYSTEMS INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of INDUSTRIAL SYSTEMS INC in 5513 HIGHWAY 348, DELTA, CO 81416 (NAICS 237120). OSHA activity number 339058273.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDUSTRIAL SYSTEMS INC
- Site address
- 5513 HIGHWAY 348
- City
- DELTA
- State
- CO
- ZIP
- 81416
- Mailing
- P.O. BOX 532, DELTA, CO 81416
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 42
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.106 E02 II B 2
- Issued
- Jun 21, 2013
- Abate by
- Jul 26, 2013
- Penalty
- Initial $1,785 · Current $1,160 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)[B](2): The quantity of liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons of Class 1B, 1C, II, or III liquids in containers: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On 5/6/13, Industrial Systems Inc did not ensure that the quantity of liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building did not exceed 120 gallons of Class 1B, 1C, II, or III liquids in containers. Employees painted metal panels. The preparation, painting, and clean-up operations used paints and solvents containing methyl amyl ketone, naphtha, xylene, and tert-butyl acetate. These paints and solvents are Class 1B flammable liquids. Approximately 1,229 gallons of flammable liquids were stored outside of cabinets or an inside storage room in the spray area of the paint shop. The employer did not ensure that the quantity of flammable liquids did not exceed 120 gallons outside of an inside storage room or cabinet. This condition exposed employees to a fire hazard.
Recent events (2)
- — I (S) $1160
- — Z (S) $1785
1910.107 E02
- Issued
- Jun 21, 2013
- Abate by
- Jul 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(2): The employer did not ensure that the quantity of flammable or combustible liquids kept in the vicinity of spraying operations was the minimum required for operations and should ordinarily not exceed a supply of 1 day or one shift: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On 5/6/13, Industrial Systems Inc did not ensure that the quantity of flammable or combustible liquids kept in the vicinity of spraying operations was the minimum required for operations and should ordinarily not exceed a supply of 1 day or one shift. Employees painted metal panels. The preparation, painting, and clean-up operations used paints and solvents containing methyl amyl ketone, naphtha, xylene, and tert-butyl acetate. These paints and solvents are Class 1B flammable liquids. Approximately 1,229 gallons of flammable liquids were stored in the spray area of the paint shop. The employer did not ensure that the quantity of flammable liquids kept in the vicinity of the spraying operation did not exceed a day's or shift's supply. This condition exposed employees to a fire hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 C08
- Issued
- Jun 21, 2013
- Abate by
- Jul 26, 2013
- Penalty
- Initial $1,785 · Current $1,160 Reduced
General-duty citation text
29 CFR 1910.107(c)(8): Portable electric lamps were used in the spraying area during spraying operations: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On and preceding 5/6/13, Industrial Systems Inc did not ensure that portable electric lamps were not used in the spraying area during spraying operations. Employees painted metal panels. The preparation, painting, and clean-up operations generated aerosols and vapors containing methyl amyl ketone, naphtha, xylene, and tert-butyl acetate. These chemicals are Class 1B flammable liquids. Employees utilized Cooper Lighting TQS1200QDR 1200 watt halogen work lights when spray painting. The work lights were not approved for a Class I, Zone 2 location. The employer did not ensure that the halogen work lights were not an ignition source. This condition exposed employees to a fire hazard.
Recent events (2)
- — I (S) $1160
- — Z (S) $1785
1910.159 C01 II
- Issued
- Jun 21, 2013
- Abate by
- Aug 25, 2013
- Penalty
- Initial $1,785 · Current $1,160 Reduced
General-duty citation text
29 CFR 1910.159(c)(1)(ii): Equipment and devices used in the design and installation of automatic sprinkler systems were not approved, as defined in 29 CFR 1910.155(c)(3): (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On and preceding 5/6/13, Industrial Systems Inc did not ensure that equipment and devices used in the design and installation of automatic sprinkler systems were approved, as defined in 29 CFR 1910.155(c)(3). Employees painted metal panels. The preparation, painting, and clean-up operations generated aerosols and vapors containing methyl amyl ketone, naphtha, xylene, and tert-butyl acetate. The work was done in a spray area. The employer had designed and installed a fire suppression system in the spray area. The spray area was a Special Occupancy location, extra hazard occupancy Group 2. The piping for the sprinklers was constructed of Cresline 1 inch PVC Schedule 40 piping. This piping does not comply with National Fire Protection Association (NFPA) 13 "Standard for the Installation of Sprinkler Systems". The employer did not ensure that the piping was approved. This condition exposed employees to a fire hazard.
Recent events (2)
- — I (S) $1160
- — Z (S) $1785
1910.1200 G08
- Issued
- Jun 21, 2013
- Abate by
- Jul 26, 2013
- Penalty
- Initial $1,785 · Current $1,161 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the material safety data sheets for each hazardous chemical in the workplace: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On and preceding 5/6/13, Industrial Systems Inc did not maintain copies of the material safety data sheets for each hazardous chemical in the workplace. Hazardous chemicals located in the workplace included, but are not limited to the following: 1. PPG Industries Amerlock 2/400 Pearl Grey Resin; 2. Valley Paint Manufacturing Copolymer Shop Coat Primer; and 3. Valley Paint Manufacturing Grey Enamel.
Recent events (2)
- — I (S) $1161
- — Z (S) $1785
1910.1200 H01
- Issued
- Jun 21, 2013
- Abate by
- Jul 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On and preceding 5/6/13, Industrial Systems Inc did not ensure that employees were provided effective information and training as specified in 29 CFR 1910.1200(h) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area. Hazardous chemicals located in the workplace included, but are not limited to the following: 1. PPG Industries Amerlock 400 AL Cure (containing xylene); 2. PPG Industries Amerlock 2 VOC Cure (containing xylene, tert-butyl acetate) 3. Methyl amyl ketone; 4. Acetone; 5. Lacquer thinner; 6. PPG Industries Amerlock 2/400 Pearl Grey Resin; 7. Valley Paint Manufacturing Copolymer Shop Coat Primer; and 8. Valley Paint Manufacturing Grey Enamel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 D01 III
- Issued
- Jun 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard in the workplace: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On and preceding 5/6/13, Industrial Systems Inc did not identify and evaluate the respiratory hazard in the workplace, in that employees painted metal panels. The preparation, painting, and clean-up operations generated aerosols and vapors containing methyl amyl ketone, naphtha, xylene, and tert-butyl acetate. The employer did not evaluate employee exposure to the vapors and aerosols. This condition potentially exposed employees to a respiratory hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E01
- Issued
- Jun 21, 2013
- Abate by
- Jul 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested, or required to use the respirator in the workplace: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On and preceding 5/6/13, Industrial Systems Inc did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested, or required to use the respirator in the workplace. Employees painted metal panels. The preparation, painting, and clean-up operations generated aerosols and vapors containing methyl amyl ketone, naphtha, xylene, and tert-butyl acetate. The employer required employees wear 3M model 6001 tight fitting air purifying full face respirators with organic vapor/P95 cartridges. Employees were not provided a medical evaluation to determine ability to use a respirator. This condition potentially exposed employees to a respiratory hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 H02 I
- Issued
- Jun 21, 2013
- Abate by
- Jul 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): The employer did not ensure that all respirators were stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and that all respirators were packed or stored to prevent deformation of the facepiece and exhalation valve: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On and preceding 5/6/13, Industrial Systems Inc did not ensure that all respirators were stored to protect them from damage, contamination, and damaging chemicals, and that all respirators were packed or stored to prevent deformation of the facepiece and exhalation valve. Employees painted metal panels. The preparation, painting, and clean-up operations generated aerosols and vapors containing methyl amyl ketone, naphtha, xylene, and tert-butyl acetate. The employer required employees wear 3M model 6001 tight fitting air purifying full face respirators with organic vapor/P95 cartridges. The respirators were stored by hanging from hooks or wrapped in towels in the area where paints and other chemicals were stored or mixed. The employer did not ensure that respirators were stored to protect them from contamination and that respirators were stored to prevent deformation of the facepiece. This condition potentially exposed employees to a respiratory hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K01
- Issued
- Jun 21, 2013
- Abate by
- Jul 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective, comprehensive, understandable, annual respirator training to employees who are required to use respirators: (a) Industrial Systems Inc, at 5513 Highway 348, Delta, CO: On and preceding 5/6/13, Industrial Systems Inc did not provide effective, comprehensive, understandable, annual respirator training to employees who are required to use respirators. Employees painted metal panels. The preparation, painting, and clean-up operations generated aerosols and vapors containing methyl amyl ketone, naphtha, xylene, and tert-butyl acetate. The employer required employees wear 3M model 6001 tight fitting air purifying full face respirators with organic vapor/P95 cartridges. The employer did not provide comprehensive annual respirator training. This condition potentially exposed employees to a respiratory hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Industrial Systems INC
View Industrial Systems INC's full OSHA safety record →
More inspections in this industry (NAICS 237120)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339058273.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.