Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: STODDARD BAPTIST NURSING HOME

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STODDARD BAPTIST NURSING HOME in 1818 NEWTON ST NW, WASHINGTON, DC 20010 (NAICS 623110). OSHA activity number 339064867.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stoddard Baptist Nursing Home for free Get an email when a new federal OSHA severe-injury report for Stoddard Baptist Nursing Home is published. One employer, no account, unsubscribe in one click.
Site address
1818 NEWTON ST NW
City
WASHINGTON
State
DC
ZIP
20010
Mailing
1818 NEWTON ST NW, WASHINGTON, DC 20010
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 20, 2013
Penalty
Initial $1,418 · Current $709 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":   a) On May 8, 2013 and at times prior thereto; Maintenance Shop; exits doors were not properly or clearly identified as "EXIT" doors in an event of an emergency.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (S) $709
  • · Z (S) $1418

1910.37 B05

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):   a) On May 8, 2013 and at times prior thereto; Maintenance Shop; doors in the maintenance department that are not exits were not so indicated.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 C01

Serious Gravity 1 3 instances 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 20, 2013
Penalty
Initial $1,418 · Current $709 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a) On May 8, 2013 and at times prior thereto; Maintenance Shop; extinguishers were not properly identified in case of an emergency event.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (S) $709
  • · Z (S) $1418

1910.157 G01

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    a) On May 8, 2013 and at times prior thereto; Maintenance Shop; employees who are required to use a portable fire extinguisher had not been properly trained on how to safely handle and use the equipment to extinguish incipient fires.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.213 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 20, 2013
Penalty
Initial $2,363 · Current $1,181 Reduced
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:     a) On May 8, 2013 and at times prior thereto; Maintenance Shop; employees were using a Delta table saw that was not equipment with anti-restart switch to prevent it from accidental restart in the event of power loss and restoration.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (S) $1181
  • · Z (S) $2363

View Stoddard Baptist Nursing Home's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339064867.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.