Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTH TEXAS ERECTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTH TEXAS ERECTORS, INC. in 11000 FISCHER ROAD, VON ORMY, TX 78073 (NAICS 238120). OSHA activity number 339069296.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch South Texas Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for South Texas Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11000 FISCHER ROAD
City
VON ORMY
State
TX
ZIP
78073
Mailing
8531 LESLIE RD SUITE 105, SAN ANTONIO, TX 78254
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
30
Ownership type
A

2 citations on file for this inspection.

1926.451 B02

Other-than-serious 1 instance 1 exposed
Issued
Jul 3, 2013
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide:    On May 15, 2013, an employee was exposed to a fall hazard from approximately 15' above ground level below while doing steel erection work and standing on the top rail of a SkyJack scissor lift.
Recent events (2)
  • — I (O) $2450
  • — Z (S) $3500

1926.453 B02 IV

Repeat Gravity 5 1 instance 1 exposed
Issued
Jul 3, 2013
Penalty
Initial $7,000 · Current $4,000 Reduced
29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket:    On May 15, 2013, at this construction site, an employee was exposed to a fall hazard from approximately 30 feet to the ground level below while conducting steel erection work standing on the midrail of a JLG aerial lift basket.    The South Texas Erectors, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.453(b)(2)(iv), which was contained in OSHA inspection number 315488189, citation number 1, item number 2a and was affirmed as a final order on September 14, 2011, with respect to a workplace located at 101 N. Dixieland Rd. Harlingen TX 78552.
Recent events (2)
  • — I (R) $4000
  • — Z (R) $7000

View South Texas Erectors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339069296.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.