DES PLAINES, IL —
OSHA Inspection: ADAM MASONRY GROUP, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADAM MASONRY GROUP, INC. in 1113 LEE ST., DES PLAINES, IL 60016 (NAICS 238140). OSHA activity number 339070161.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADAM MASONRY GROUP, INC.
- Site address
- 1113 LEE ST.
- City
- DES PLAINES
- State
- IL
- ZIP
- 60016
- Mailing
- 313 W. CHERYL LANE, PALATINE, IL 60067
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 C01
- Issued
- May 29, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $2,200 · Current $880 Reduced
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffold(s) with a height to base width (including outrigger supports) ratio greater than four to one (4:1) was not restrained from tipping by guying, tying, bracing, or equivalent means: a) Employees were exposed to fall hazards of 19.8 feet while working on a tubular welded frame scaffold which was not restrained from tipping by any means. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $880
- — Z (S) $2200
1926.452 C02
- Issued
- May 29, 2013
- Abate by
- Jun 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) Employees were exposed to fall hazards of 19.8 while working from a tubular welded frame scaffold which did not have any type of bracing connecting the two sections of scaffolding. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- May 29, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $1,760 · Current $704 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) Employees working from tubular welded frame scaffolding were not provided with proper access to a work platform being used at an elevation of approximately 19.8 feet above the ground. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $704
- — Z (S) $1760
1926.451 G01
- Issued
- May 29, 2013
- Abate by
- Jun 4, 2013
- Penalty
- Initial $3,080 · Current $1,216 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) Employees were exposed to the hazard of falling while performing masonry work from tubular welded frame scaffold platform elevated approximately 19.8 feet above the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1216
- — Z (S) $3080
More inspections at Adam Masonry Group, INC.