BARRIGADA, GU ·
OSHA Inspection: FINE DEVELOPMENT CORPORATION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of FINE DEVELOPMENT CORPORATION in ROUTE 16, LOT 5211-2-2-1-R2-1, BARRIGADA, GU 96913 (NAICS 238220). OSHA activity number 339073587.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FINE DEVELOPMENT CORPORATION
- Site address
- ROUTE 16, LOT 5211-2-2-1-R2-1
- City
- BARRIGADA
- State
- GU
- ZIP
- 96913
- Mailing
- P.O. BOX 26297, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.403 B02
- Issued
- Jul 16, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: At the project site (2nd floor, interior) on or about May 20, 2013, where an electrical box with a ground fault circuit interrupter receptacle, was used as part of an extension cord. The box with receptacle is designed to be installed/mounted in or on a wall. Employees used the extension cord to provide power to the Bosch 11255VSR BULLDOG Xtreme Rotary Hammer, Serial Number 301169840.
Recent events (2)
- · I (S) $810
- · Z (S) $1080
1926.405 B01
- Issued
- Jul 16, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: At the project site (2nd floor, interior) on or about May 20, 2013, where the unused opening in the electrical box was not effectively closed. Employees used the extension cord to provide power to the Bosch 11255VSR BULLDOG Xtreme Rotary Hammer, Serial Number 301169840.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Fine Development Corporation
View Fine Development Corporation's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339073587.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.