Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JAE HOON CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAE HOON CORPORATION in LOT 2176 - 311 BAMBA WAY COOL SPOT BLDG, BARRIGADA, GU 96921 (NAICS 445110). OSHA activity number 339073603.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JAE Hoon Corporation — free Get an email when a new federal OSHA severe-injury report for JAE Hoon Corporation is published. One employer, no account, unsubscribe in one click.
Site address
LOT 2176 - 311 BAMBA WAY COOL SPOT BLDG
City
BARRIGADA
State
GU
ZIP
96921
Mailing
P.O. BOX 25356, BARRIGADA, GU 96921
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445110
Employees
44
Ownership type
A

5 citations on file for this inspection.

1910.23 E03 IV

Serious Gravity 5 1 instance 25 exposed
Issued
Sep 19, 2013
Abate by
Oct 1, 2013
Penalty
Initial $3,500 · Current $2,700 Reduced
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types were not of such construction that the completed structure was not capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail:    Second floor of storage room above first floor blocked exit:  On March 20, 2013, the left section of the railing in front of the freight elevator was not secured with latches provided, exposing employees to a fall hazard to the lower floor.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3500

1910.36 D01

Serious Gravity 10 3 instances 25 exposed
Issued
Sep 19, 2013
Abate by
Oct 1, 2013
Penalty
Initial $4,900 · Current $3,200 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:      a)    Storage Room Main Floor: On May 20, 2013, the exit door leading to the street was blocked with boxes of food items.       b)    Storage room second floor next to the circuit breaker panel: On May 20, 2013, the exit door next to the circuit breaker panel and leading to exit stairs was locked.       c)    Storage room second floor at the opposite end from the circuit breaker panel: On May 20, 2013, the exit door was locked.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $4900

1910.37 A03

Serious Gravity 10 1 instance 25 exposed
Issued
Sep 19, 2013
Abate by
Oct 1, 2013
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:     Storage Room Main Floor: On May 20, 2013, the exit door leading to the street was blocked with boxes of food items at least two rows deep.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 19, 2013
Penalty
Initial $2,975 · Current $2,100 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     Second floor meat cutting area:  On March 20, 2013, the cutting blade on the Biro Meat Saw was open 3 inches, exposing the employee to amputation hazards.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2975

1910.305 B01 II

Other-than-serious 1 instance 25 exposed
Issued
Sep 19, 2013
Abate by
Oct 1, 2013
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:     Second Floor: On May 20, 2013, the electric circuit breaker panel was missing two switch panel plugs, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2100

View JAE Hoon Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339073603.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.