Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JB SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JB SERVICE in GROUND FLOOR, TAKAGI & ASSOCIATES BUILDING LOT 5086-1-3-1-NEW, TAMUNING, GU 96913 (NAICS 238910). OSHA activity number 339076762.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JB Service — free Get an email when a new federal OSHA severe-injury report for JB Service is published. One employer, no account, unsubscribe in one click.
Establishment
JB SERVICE
Site address
GROUND FLOOR, TAKAGI & ASSOCIATES BUILDING LOT 5086-1-3-1-NEW
City
TAMUNING
State
GU
ZIP
96913
Mailing
PO BOX 8796, TAMUNING, GU 96931
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 16, 2013
Abate by
Aug 9, 2013
Penalty
Initial $1,080 · Current $540 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.     At the ground floor of the Takagi & Associates building on May 22, 2013, where no assured equipment grounding conductor program or no ground-fault circuit-interrupter provided when an extension cord was used to supply power to a Makita Demolition Hammer, Model Hm1307CB , Serial Number 10897.
Recent events (2)
  • — I (S) $540
  • — Z (S) $1080

1926.701 B

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 16, 2013
Abate by
Aug 9, 2013
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:   At the ground floor of the Takagi & Associates building on May 22, 2013, where protruding rebar was not guarded to eliminate the hazard of impalement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1800

1926.25 A

Other-than-serious 1 instance 2 exposed
Issued
Jul 16, 2013
Abate by
Aug 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.25(a): During the course of construction, alteration, or repairs,  debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:   At the ground floor of the Takagi & Associates building on May 22, 2013, concrete debris was not kept clear from the main entrance to the building. Employee walked on the concrete debris to enter and exit the work area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View JB Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339076762.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.