Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANTHONY & SONS BAKERY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ANTHONY & SONS BAKERY, INC. in 20 LUGER ROAD, DENVILLE, NJ 07834 (NAICS 311812). OSHA activity number 339077281.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anthony & Sons Bakery, INC. — free Get an email when a new federal OSHA severe-injury report for Anthony & Sons Bakery, INC. is published. One employer, no account, unsubscribe in one click.
Site address
20 LUGER ROAD
City
DENVILLE
State
NJ
ZIP
07834
Mailing
20 LUGER ROAD, DENVILLE, NJ 07834
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
188
Ownership type
A

7 citations on file for this inspection.

1910.27 C04

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 1, 2013
Abate by
Nov 29, 2013
Penalty
Initial $5,940 · Current $4,500 Reduced
29 CFR 1910.27(c)(4):     The employer did not install fixed ladders with at least 7 inches of clearence from the centerline of the rung to the nearest permanent object in the back of the ladder.     a)  Establishment - 2 Crossover Bridges with 1 adjacent to the Gemini conveyor system and one adjacet to the Rack Loader:    Employees were exposed to falls as each Crossover Bridge had only 2 inches of clearance from the centerline of the top rung to a retrofitted metal shield behind the rung.                                           Violation observed on or about 5/20/2013.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $5940

1910.147 C04 II B

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 1, 2013
Abate by
Nov 21, 2013
Penalty
Initial $6,930 · Current $4,500 Reduced
29 CFR 1910.147(c)(4)(ii)(B):     The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    a)  Establishment - Production Floor:    The employer's energy control procedure did not provide sufficient detail and specificity for employees to safely and effectively control energy sources during the servicing or maintenance of equipment, such as the Gemini System Rack Loader machinery.                                                Violation disclosed on or about 5/20/13.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $6930

1910.147 C06 I

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 1, 2013
Abate by
Nov 21, 2013
Penalty
Initial $3,960 · Current $2,500 Reduced
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a)  Establishment:      The employer did not conduct a periodic inspection of the energy control procedures.                                                        Violation occurred on or about 05/20/2013.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3960

1910.147 C07 I

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 1, 2013
Abate by
Nov 21, 2013
Penalty
Initial $3,960 · Current $2,500 Reduced
29 CFR 1910.147(c)(7)(i):     The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    a)  Establishment:      Employee(s) required to perform maintenance, service and repair to equipment, such as but not limited to the Gemini Systems Rack Loader, were not provided training on machine specific energy control procedures.                                                         Violation disclosed on or about 5/20/2013.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3960

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 1, 2013
Abate by
Nov 29, 2013
Penalty
Initial $3,960 · Current $2,000 Reduced
29 CFR 1910.178(l)(1)(i):     The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a)  Establishment:    Employees were not trained prior to being permitted to operate a powered industrial vehicle.                                        Violation observed on or about 5/20/2013.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3960

1910.212 A01

Serious Gravity 10 2 instances 1 exposed
Issued
Nov 1, 2013
Abate by
Nov 21, 2013
Penalty
Initial $6,930 · Current $2,500 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by moving parts and nip points:      a)  Establishment - Bakery Dept. - Gemini Loader:    The Banner Machine Guard Safety Switch was not engaged and did not shut power to the machinery when the cage was opened.                                    Violation occurred on or about 5/16/2013.          b)  Establishment - Bakery Dept. - Winkler System:    The Winkler System panning table was not guarded to prevent employees hands from coming in contact with pinch points.                                       Violaton observed on or about 5/20/2013.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $6930

1910.305 B01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 1, 2013
Penalty
Initial $4,950 · Current $1,102 Reduced
29 CFR 1910.305(b)(1)(i):     Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:      a)  Establishment - Production Floor. - Gemini System Conveyor:    Conductors entering a 480 volt cabinet were not enclosed exposing employees to electric shock.                              Violation observed on or about 5/20/2013.      b)  Establishment - Production Floor. - Gemini System Conveyor:    Conductors entering a 480 volt cabinet were not enclosed exposing employees to electric shock.                             Violation observed on or about 5/20/2013.
Recent events (2)
  • — I (S) $1102
  • — Z (S) $4950

View Anthony & Sons Bakery, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339077281.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.