Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRINITY YACHTS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TRINITY YACHTS, LLC in 13085 SEAWAY ROAD, GULFPORT, MS 39503 (NAICS 336611). OSHA activity number 339077893.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trinity Yachts, LLC — free Get an email when a new federal OSHA severe-injury report for Trinity Yachts, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TRINITY YACHTS, LLC
Site address
13085 SEAWAY ROAD
City
GULFPORT
State
MS
ZIP
39503
Mailing
13085 SEAWAY ROAD, GULFPORT, MS 39503
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
617
Ownership type
A

19 citations on file for this inspection.

1910.29 A03 VIII

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 12, 2013
Abate by
Nov 19, 2013
Penalty
Initial $4,400 · Current $3,000 Reduced
29 CFR 1910.29(a)(3)(viii): A climbing ladder or stairway was not provided for proper access and egress:      (a) Bay 4 - On or about May 16, 2013 employee worked from mobile scaffold 12' 2" above floor and the scaffold was not equipped with safe access and egress.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4400

1910.179 L03 I

Serious Gravity 5 2 instances 50 exposed
Issued
Nov 12, 2013
Abate by
Dec 4, 2013
Penalty
Initial $4,400 · Current $3,000 Reduced
29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed:     (a) Erection Way - On or about May 16, 2013 P&H gantry crane's travel alarms were not functional.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4400

1910.254 D09 II

Serious Gravity 5 8 instances 10 exposed
Issued
Nov 12, 2013
Abate by
Nov 19, 2013
Penalty
Initial $5,500 · Current $3,200 Reduced
29 CFR 1910.254(d)(9)(ii): Machines which had become wet were not thoroughly dried and tested before being used:     (a) Erection Way - During the period May 1 through May 30, 2013 welding machines exposed to rain were not thoroughly dried and tested prior to use.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $5500

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 12, 2013
Abate by
Nov 19, 2013
Penalty
Initial $4,400 · Current $2,500 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     (a) Barge TC71 - On or about May 16, 2013 a green 3-way wall outlet plug adapter was in use in industrial setting.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4400

1910.303 F02

Serious Gravity 1 6 instances 50 exposed
Issued
Nov 12, 2013
Abate by
Nov 26, 2013
Penalty
Initial $3,300 · Current $2,000 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     (a) Entrance to PSV 1 - On or about May 16, 2013 six circuit breakers in panel were not labeled.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3300

1910.303 G02 I

Serious Gravity 5 1 instance 15 exposed
Issued
Nov 12, 2013
Abate by
Nov 19, 2013
Penalty
Initial $4,400 · Current $3,400 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:      (a) PSV 1 - On or about May 16, 2013 job made 120 volt electrical spider had its panel door open exposing live parts.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $4400

1910.305 B01 II

Serious Gravity 1 1 instance 10 exposed
Issued
Nov 12, 2013
Penalty
Initial $3,300 · Current $1,900 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed:     (a) Entrance to PSV 1 - On or about May 16, 2013 employees were exposed to hazard of electric shock when an unclosed panel had a breaker missing from panel and no panel blank was in place.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3300

1910.334 A04

Serious Gravity 5 13 instances 20 exposed
Issued
Nov 12, 2013
Abate by
Dec 4, 2013
Penalty
Initial $5,500 · Current $3,000 Reduced
29 CFR 1910.334(a)(4):  Portable electric equipment and flexible cords used in highly conductive work locations (such a those inundated with water or other conductive liquids), or in job locations where employees are likely to contact water or conductive liquids, were not approved for those locations:      (a) Erection Way - On or about May 30, 2013 flexible cords were submerged in water where the cords passed under the railway for gantry crane.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5500

1915.81 B01 IV A

Serious Gravity 1 12 instances 35 exposed
Issued
Nov 12, 2013
Abate by
Dec 4, 2013
Penalty
Initial $3,300 · Current $1,700 Reduced
29 CFR 1915.81(b)(1)(iv)(A): Each hose and cord was not placed above walkways or in a location that will prevent injury to employees and damage to the hoses and cords:     (a) Bay 4, Barge - On or about May 16, 2013 multiple cords and hoses were laying on deck.     (b) Erection Way - On or about May 30, 2013 section of hoses and cords were laying on walkway.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $3300

1915.81 B01 IV C

Serious Gravity 1 1 instance 23 exposed
Issued
Nov 12, 2013
Abate by
Nov 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1915.81(b)(1)(iv)(C):   The employer did not place a cover or crossover on each hose and cord on the walkway to prevent injury to employees and damage to the hoses and cords:   (a) North of Erection Way - On or about May 16, 2013 cords, welding leads and hoses were on ground across roadway exposed to vehicular traffic.   (b) Erection Way - On or about May 30, 2013 cords and hoses placed in a manner where they could be damaged by edges of metal cover (crossover).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.112 C01 I

Serious Gravity 1 3 instances 4 exposed
Issued
Nov 12, 2013
Abate by
Feb 3, 2014
Penalty
Initial $3,300 · Current $2,300 Reduced
29 CFR 1915.112(c)(1)(i):  Employer did not ensure chain and chain slings have permanently affixed and legible identification markings as prescribed by the manufacturer indicating the recommended safe working load for the angle upon which it was based:     (a) Erection Way - On or about May 16, 2013 chain slings used to lift wing wall were not tagged.     (b) Bay 7 - On or about May 30, 2013 employees were using chain sling that were not tagged.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $3300

1915.112 C02

Serious Gravity 1 3 instances 4 exposed
Issued
Nov 12, 2013
Abate by
Feb 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1915.112(c)(2): Each chain sling did not bear an indication of the month in which it was thoroughly inspected:    (a)  Erection Way - On or about May 16, 2013 chain slings used to lift wing wall did not have an inspection tag.    (b)  Bay 7 - On or about May 30, 2013 chain sling used to lift scaffold components did not have an inspection tag.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.116 J

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 12, 2013
Penalty
Initial $5,500 · Current $3,500 Reduced
29 CFR 1915.116(j): Loads were suspended over the heads of employees:     (a) Erection Way - On or about May 16, 2013 employee was working at the edge of SW corner of Mod as crane was placing a wing tank.  Employee's position on the Mod was below the wing tank as it tilted into position.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5500

1910.254 D09 III

Repeat Gravity 5 3 instances 2 exposed
Issued
Nov 12, 2013
Abate by
Nov 19, 2013
Penalty
Initial $55,000 · Current $29,000 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:     (a)  Erection Way - On or about May 16, 2013 Lincoln CV-305 had damaged welding cord with exposed conductors.     (b)  Erection Way - On or about May 30, 2013 Lincoln CV-305 and DC-600 had damaged cords with exposed conductors.     (c)  Barge T-83 - On or about May 29, 2013 welding machines in use had damaged welding leads.     Trinity Yachts was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.254(d)(9)(iii), which was contained in OSHA Inspection Number 313631350, Citation Number 1, Item Number 2b and was affirmed as a final order on November 1, 2010, with respect to a workplace located at 13085 Seaway Road, Gulfport, MS  39503.
Recent events (2)
  • — I (R) $29000
  • — Z (R) $55000

1915.73 B

Repeat Gravity 5 7 instances 20 exposed
Issued
Nov 12, 2013
Abate by
Nov 19, 2013
Penalty
Initial $27,500 · Current $15,000 Reduced
29 CFR 1915.73(b): When employees were working in the vicinity of flush manholes and other small openings of comparable size in the deck and other working surfaces, such openings were not suitably covered or guarded to a height of not less than 30 inches:     (a) Bay 4, Barge - On or about May 16, 2013 four hatch openings (man holes) near center of barge were open and no guardrails installed.     (b) Erection Way, Barge - On or about May 30, 2013 two hatch openings (man holes) near center and one on port side were open with no guardrails installed.     Trinity Yachts was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1915.73(b), which was contained in OSHA Inspection Number 315302646, Citation Number 1, Item Number 2 and was affirmed as a final order on June 22, 2011, with respect to a workplace located at 13085 Seaway Road, Gulfport, MS  39503.
Recent events (2)
  • — I (R) $15000
  • — Z (R) $27500

1915.73 D

Repeat Gravity 1 1 instance 1 exposed
Issued
Nov 12, 2013
Penalty
Initial $16,500 · Current $10,000 Reduced
29 CFR 1915.73(d): When employees were exposed to unguarded edges of decks, platforms, flats, or similar flat surfaces, more than 5 feet above a solid surface, the edges were not guarded by adequate guardrails meeting the requirements of 29 CFR 1915.71(j)(1) and (2):     (a)  Erection Way - On or about May 16, 2013 employee was exposed to a fall of 8'6" while working at the edge of SW corner of Mod without guardrails, personal fall arrest system or other fall protection.     Trinity Yachts was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1915.73(d), which was contained in OSHA Inspection Number 315302646, Citation Number 1, Item Number 2 and was affirmed as a final order on June 22, 2011, with respect to a workplace located at 13085 Seaway Road, Gulfport, MS  39503.
Recent events (2)
  • — I (R) $10000
  • — Z (R) $16500

1915.81 C03

Deleted Repeat Gravity 1 2 instances 11 exposed
Issued
Nov 12, 2013
Abate by
Dec 26, 2013
Penalty
Initial $16,500 · Current $0 Reduced
29 CFR 1915.81(c)(3): Floors were not maintained, so far as practicable, in a dry condition.   (a) East Side of Shop - On or about May 30, 2012 large section of bay 8 was covered by water.   (b) Shop - On or about May 30, 2013 water covered section of floor in tool room near safety office.   Trinity Yachts was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.22(a)(2), which was contained in OSHA Inspection Number 311421267, Citation Number 1, Item Number 2b and was affirmed as a final order on February 8, 2010, with respect to a workplace located at 13085 Seaway Road, Gulfport, MS 39503.
Recent events (2)
  • — I (R) $0
  • — Z (R) $16500

1910.179 B05

Other-than-serious 2 instances 50 exposed
Issued
Nov 12, 2013
Abate by
Dec 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.179(b)(5): Rated load markings on crane(s) were not clearly legible on each side from the ground or the floor:   (a) Erection Way - On or about May 16, 2013 west gantry crane's load rating signs were not legible.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1915.56 E

Other-than-serious 8 instances 100 exposed
Issued
Nov 12, 2013
Abate by
Dec 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1915.56(e): Arc welding and cutting operations were not shielded by noncombustible or flameproof screens to protect employees in the vicinity from the direct rays of the arc:   (a) Bays 4, 5, 6 and 7  - On or about May 16, 2013 employees were exposed to UV radiation hazard when cutting and welding operations took place without the use of welding screens to shield employees from the direct rays of the arc.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Trinity Yachts, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339077893.