ASAN, GU —
OSHA Inspection: PACIFIC INTERNATIONAL INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PACIFIC INTERNATIONAL INC. in 480 MARINE DRIVE, ASAN, GU 96910 (NAICS 493110). OSHA activity number 339081465.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PACIFIC INTERNATIONAL INC.
- Site address
- 480 MARINE DRIVE
- City
- ASAN
- State
- GU
- ZIP
- 96910
- Mailing
- P.O. BOX EE, HAGATNA, GU 96932
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 9
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 P01
- Issued
- Aug 20, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). Warehouse Floor: On May 22, 2013, the Crown CA Sideshifter 55F-SS-A062 Serial Number 1A202850 reverse alarm was not operational.
Recent events (1)
- — Z (S) $1200
1910.178 Q07
- Issued
- Aug 20, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined at least daily before being placed in service. Warehouse Floor: On May 22, 2013, a daily inspection was not conducted on the Crown CA Sideshifter 55F-SS-A062 Serial Number 1A202850 with a reverse alarm that was not operational.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Aug 20, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Shampoo storage room: There was a flexible cord energizing the ceiling light, exposing employees to a fire hazard.
Recent events (1)
- — Z (S) $1200
More inspections at Pacific International INC.
View Pacific International INC.'s full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339081465.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.