TAMUNING, GU —
OSHA Inspection: UNIVERSAL AIR SUPPLY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNIVERSAL AIR SUPPLY, INC. in 159-B SIKET ROAD, TAMUNING, GU 96931 (NAICS 444190). OSHA activity number 339081515.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL AIR SUPPLY, INC.
- Site address
- 159-B SIKET ROAD
- City
- TAMUNING
- State
- GU
- ZIP
- 96931
- Mailing
- PO BOX 8638, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Sep 11, 2013
- Abate by
- Sep 23, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Warehouse loft above showroom: On May 23, 2013, there were no guardrails protecting employees working in the loft area from falling to the warehouse floor.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.178 P01
- Issued
- Sep 11, 2013
- Abate by
- Sep 23, 2013
- Penalty
- Initial $1,200 · Current $900 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). Warehouse Floor: On May 23, 2013, the Clark Model CGC25 Serial Number C365L-1189-9464F3f forklift horn was not operational and the tires needed to be replaced.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.178 Q07
- Issued
- Sep 11, 2013
- Abate by
- Sep 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). Warehouse Floor: On May 23, 2013, a daily inspection was not conducted on the Clark Model CGC25 Serial Number C365L-1189-9464F3F forklift with a horn that was not operational and tires that needed to be replaced.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 444190)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339081515.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.