BRONX, NY ·
OSHA Inspection: SPARKZ IRON WORKS CORP.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SPARKZ IRON WORKS CORP. in 519 EAST 132 STREET, BRONX, NY 10454 (NAICS 332111). OSHA activity number 339083230.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPARKZ IRON WORKS CORP.
- Site address
- 519 EAST 132 STREET
- City
- BRONX
- State
- NY
- ZIP
- 10454
- Mailing
- 519 EAST 132 STREET, BRONX, NY 10454
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 2
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.101 B
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $2,400 · Current $900 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, Section 3.3.8 in that cylinders were not protected against heavy moving heavy moving objects striking or falling on them: a) Outdoor Yard - Caged Storage Area: Oxygen, acetylene and propane cylinders were not secured to prevent them from being struck or knocked over; on or about 5/22/13.
Recent events (3)
- · F (S) $900
- · C (S) $2400
- · Z (S) $2400
1910.253 B02 IV
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a) Outdoor Yard - Caged Storage Area: An oxygen cylinder and three acetylene cylinders were stored without valve caps in place; on or about 5/22/13. b) Inside the Building: An oxygen cylinder and an acetylene cylinder were stored together with without valve caps in place; on or about 5/22/13.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.253 B04 III
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) Outdoor Yard - Caged Storage Area: Oxygen cylinders were stored next to acetylene and propane cylinders and not separated as required by the standard; on or about 5/22/13. b) Inside the Building: An oxygen cylinder was stored with an acetylene cylinder and not separated as required by the standard; on or about 5/22/13.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.106 E02 IV A
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $1,600 · Current $450 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(a): 29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not kept in covered containers when not actually in use: a) Inside the Building - Righ Corner Back of Shop: A pail containing flammable paint (Sherwin Williams Opex Production Lacquer) was stored in an uncovered container; on or about 5/22/13.
Recent events (3)
- · F (S) $450
- · C (S) $1600
- · Z (S) $1600
1910.106 E09 III
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) Inside the Building: Combustible waste materials (e.g., cups and brushes coated in flammable paint) were disposed of in an open plastic garbage pail and not kept covered; on or about 5/22/13.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.1200 E01
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $1,600 · Current $450 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Entire Company: Employees handled and used hazardous chemicals including but not limited to: oxygen, acetylene, propane, lacquer, etc. and the employer did not develop and implement a written hazard communication program; on or about 5/22/13.
Recent events (3)
- · F (S) $450
- · C (S) $1600
- · Z (S) $1600
1910.1200 G01
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a) Entire Company: Employees handled and used hazardous chemicals including but not limited to: oxygen, acetylene, propane, lacquer, etc. and the employer did not have safety data sheets for these chemicals; on or about 5/22/13.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Entire Company: Employees handled and used hazardous chemicals including but not limited to: oxygen, acetylene, propane, lacquer, etc. and the employer did not provide information and training to employees as required by the standard; on or about 5/22/13.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.157 C04
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use: a) Inside Shop: A Buckeye portable dry chemical fire extinguisher (Model: 10-HI-SA80-ABC) was found discharged and not maintained in a fully charge operable condition; on or about 5/22/13.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
1910.157 E03
- Issued
- Oct 22, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) Inside Shop: A Buckeye portable dry chemical fire extinguisher (model: 10-HI-SA80-ABC) was not subjected to an annual maintenance check; on or about 5/22/13.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
More inspections at Sparkz Iron Works Corp.
View Sparkz Iron Works Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332111)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339083230.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.