HOLMDEL, NJ —
OSHA Inspection: COSMETIC ESSENCE, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of COSMETIC ESSENCE, LLC in 2182 ROUTE 35 SOUTH, HOLMDEL, NJ 07733 (NAICS 325620). OSHA activity number 339084584.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COSMETIC ESSENCE, LLC
- Site address
- 2182 ROUTE 35 SOUTH
- City
- HOLMDEL
- State
- NJ
- ZIP
- 07733
- Mailing
- 2182 HIGHWAY 35, HOLMDEL, NJ 07733
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325620
- Employees
- 350
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.215 A04
- Issued
- Jul 26, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) Maintenance Shop: Employees used a Baldor Model # 7306 without a work rest for the grinding of metal parts, on or about 5/24/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $2400
- — Z (S) $4000
1910.215 B09
- Issued
- Jul 26, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Maintenance Shop: Employees used a Baldor Model # 7306 to grind metal parts. The distance between the abrasive wheel and the end of the peripheral member was greater that ¼", on or about 5/24/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $4000
1910.303 B02
- Issued
- Jul 26, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $15,000 · Current $9,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Monoblock Room / Line 38: A 4" X 4" metal receptacle box powering a Sollas 20 packaging machine was used as a temporary flexible cord , on or about 5/24/13. b) Monoblock Room / Line 38: A 4" X 4" metal receptacle box powering a Sollas 20 packaging machine was used as a temporary flexible cord, on or about 5/24/13. COSEMTIC ESSENCE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD. ITS EQUIVALENT , OR ESSENTIALLY SIMILAR STANDARD 1910.303(b)(2), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314806928, CITATION 01, ITEM NUMBER 03. THIS VIOLATION BECAME FINAL ORDER ON 12/14/2010. IN ADDITION TO ABATEMENT CERTIFICATION THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLAY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (R) $9000
- — Z (R) $15000
1910.305 G01 IV A
- Issued
- Jul 26, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $15,000 · Current $9,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Rotary Room / Line 21: An electrical power strip was used as permanent wiring to power the conveyor belt machine and Sollas 20 Packaging machine, on or about 5/24/13. b) Rotary Room / Line 4: An electrical power strip was used as permanent wiring to power the conveyor belt machine and Sollas 20 packaging machine, on or about 5/24/13. c) Bulk Supply Room: An electrical power strip was used as permanent wiring to power a refrigerator, on or about 5/24/13. d) Bulk Supply Room: An electrical power strip was used as permanent wiring to power a overhead lamp, on or about 5/24/13. COSEMTIC ESSENCE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD. ITS EQUIVALENT , OR ESSENTIALLY SIMILAR STANDARD 1910.303(G)(1)(iv)(A), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314806928, CITATION 01, ITEM NUMBER 05. THIS VIOLATION BECAME FINAL ORDER ON 12/14/2010. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 190.19.
Recent events (2)
- — I (R) $9000
- — Z (R) $15000
More inspections at Cosmetic Essence, LLC
View Cosmetic Essence, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325620)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339084584.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.