POTTSTOWN, PA ·
OSHA Inspection: D.W. ACCOR
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of D.W. ACCOR in 191 S. KEIM ST., POTTSTOWN, PA 19464 (NAICS 332618). OSHA activity number 339088650.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D.W. ACCOR
- Site address
- 191 S. KEIM ST.
- City
- POTTSTOWN
- State
- PA
- ZIP
- 19464
- Mailing
- P.O. BOX 916, POTTSTOWN, PA 19464
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 3
- Ownership type
- Private (A)
Citations
20 citations on file for this inspection.
1910.110 F02 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.110(f)(2)(i): LP-Gas Containers were not stored in a manner to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons a) Forklift Area - On or about May 30, 2013, two LP gas tanks are stored on the floor in front of the electrical panel and are exposed to damage from forklift operation.
Recent events (1)
- · Z (S) $2400
1910.132 D01
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). a) 191 S. Keim St., Building 2G - On or about May 30, 2013, the employer did not perform a hazard assessment to determine the types of personal protective equipment adequate for the hazards associated with metal wire.
Recent events (1)
- · Z (S) $2400
1910.133 A01
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: a) 191 S. Keim Street, Building 2G - On or about May 30, 2013, the employer did not provide ANSI rated eye protection to employees who are exposed to eye injury from metal wire in the wire winding process.
Recent events (1)
- · Z (S) $0
1910.138 A
- Issued
- Jul 24, 2013
- Abate by
- Aug 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employes hands were exposed to hazardous condition(s). a) 191 S. Keim Street, Building 2G - On or about May 30, 2013, the employer did not provide employees with adequate hand protection while exposed to sharp ends of metal wire during the wire winding process.
Recent events (1)
- · Z (S) $0
1910.141 D02 II
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: a) 191 S. Keim Street, Building 2G - On or about May 30, 2013, employees are not provided with tepid water in the lavatories.
Recent events (1)
- · Z (S) $1200
1910.141 D02 III
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent: a) 191 S. Keim Street, Building 2G - On or about May 30, 2013, employees are not provided with hand soap to properly cleanse hands.
Recent events (1)
- · Z (S) $0
1910.141 D02 IV
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling: a) 191 S. Keim Street, Building 2G - Employees are not provided with hand towels or air dryers to properly dry hands.
Recent events (1)
- · Z (S) $0
1910.157 C04
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.157(c)(4): The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use. a) 191 S. Keim Street., Building 2G - On or about May 30, 2013, a portable fire extinguisher was not fully charged and had not been inspected since 1995.
Recent events (1)
- · Z (S) $1600
1910.178 L01 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) 191 S. Keim St., Building 2G - On or about May 30, 2013, the employer did not train employees prior to allowing them to operate a LP gas Tow Motor T50 forklift.
Recent events (1)
- · Z (S) $1600
1910.178 P01
- Issued
- Jul 24, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). a) 191 S. Keim Street, Building 2G - On or about May 30, 2013, the brakes on the Tow Motor T50 propane forklift are in operable. b) 191 S. Keim Street, Building 2G - On or about May 30, 2013, the hydraulic system on the Tow Motor T50 propane forklift was leaking and had not been taken out of service or repaired.
Recent events (1)
- · Z (S) $2000
1910.215 A01
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s). a) 191 S. Keim Street, Building 2G - On or about May 30, 2013, the abrasive wheel on the Micro Products Co. Precision Welder is not provided with a guard to protect employees if the wheel would break.
Recent events (1)
- · Z (S) $2400
1910.219 C04 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) 191 S. Keim Street, Building 2G - On or about May 30, 2013, the projecting shaft of the wire winding machines projects more than 1/2 the diameter and doesn't have a smooth edge.
Recent events (1)
- · Z (S) $1600
1910.219 F03
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) 191 S. Keim Street, Building 2G - On or about May 30, 2013, the chain on the wire winding machines was not guarded to prevent employees from coming into contact with the moving part as it spins up to 60 mph.
Recent events (1)
- · Z (S) $1600
1910.303 G02 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) 191 S. Keim St., Building 2G - On or about May 30, 2013, unused openings underneath the electrical panel near the office were not protected from employees accidently coming into contact with the internal electrical wires. b) 191 S. Keim St., Building 2G - On or about May 30, 2013, an electrical outlet has tape placed over the outlet plug to prevent employees from using the faulty electrical outlet.
Recent events (1)
- · Z (S) $1600
1910.305 B01
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Forklift Area - On or about May 30, 2013, a Square D electrical panel, 100 amps and 120/205 volts, has a knockout missing exposing employees to electrical hazard when using the breaker. a) 191 S. Keim St., Building 2G - On or about May 30, 2013, the electrical wiring on the forward/reverse switch located at the wire winding machine has the wires exposed where the power is connected to the box, exposing employees to electrical shock.
Recent events (1)
- · Z (S) $1600
1910.305 J01 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact: a) 191 S. Keim St., Building 2G - On or about May 30, 2013, the electrical wiring of the overhead fluorescent lighting fixtures are not enclosed in an approved casing, exposing employees to electrical shock.
Recent events (1)
- · Z (S) $0
1910.305 G01 IV A
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Work Bench - On or about May 30, 2013, a portable extension cord with an electrical box is attached to the permanent power on the wall, strung over the entry and attached to the wall by the workbench, exposing employees to electric shock. b) Winding Machines - On or about May 30, 2013, a portable extension cord is attached to the rafters in the ceiling with staples and used as a permanent power source for a portable radio.
Recent events (1)
- · Z (S) $0
1910.334 A02 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) 191 S. Keim St., Building 2G - On or about May 30, 2013, portable electric equipment and tools were not visually inspected for defects prior to use.
Recent events (1)
- · Z (S) $2400
1910.305 G02 III
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) 191 S. Keim St., Building 2G - On or about May 30, 2013, the overhead electrical heater at the workstation, less than 7 feet high, isn't provided with strain relief. b) 191 S. Keim St., Building 2G - On or about May 30, 2013, A Craftsman disc sander has the electrical wires exposed due to lack of strain relief on the portable tool. c) 191 S. Keim St., Building 2G - On or about May 30, 2013, A Dewalt electrical drill has the electrical wires exposed due to lack of strain relief on the portable tool. d) 191 S. Keim St., Building 2G - On or about May 30, 2013, the Micro Products Co. precision welder has wires exposed due to lack of strain relief.
Recent events (1)
- · Z (S) $0
1910.303 G01
- Issued
- Jul 24, 2013
- Abate by
- Aug 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) 191 S. Keim St., Building 2G - On or about May 30, 2013, the electrical panel is blocked by storage of propane tanks, metal ramps and other items, preventing immediate access in the event of emergency.
Recent events (1)
- · Z (O) $0
More inspections at D.W. Accor
View D.W. Accor's full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339088650.