Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: D.W. ACCOR

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of D.W. ACCOR in 191 S. KEIM ST., POTTSTOWN, PA 19464 (NAICS 332618). OSHA activity number 339441461.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D.W. Accor for free Get an email when a new federal OSHA severe-injury report for D.W. Accor is published. One employer, no account, unsubscribe in one click.
Establishment
D.W. ACCOR
Site address
191 S. KEIM ST.
City
POTTSTOWN
State
PA
ZIP
19464
Mailing
P.O. BOX 916, POTTSTOWN, PA 19464
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
4
Ownership type
Private (A)

4 citations on file for this inspection.

1910.215 A01

Repeat Gravity 5 1 instance 3 exposed
Issued
Jan 28, 2014
Abate by
Feb 5, 2014
Penalty
Initial $3,520 · Current $3,520
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):  a)  191 S. Keim St., Bldg. 2G - On or about October25, 2013, the abrasive wheel on the Micro Products Co., Precision Welder is not provided with a guard to protect employees if the wheel would break.  D.W. Accor was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 908865, citation number 1, item number 7 and was affirmed as a final order on August 20, 2013, with respect to a workplace located at 191 S. Keim Street, Building 2G, Pottstown PA.
Recent events (1)
  • · Z (R) $3520

1910.305 G02 III

Repeat Gravity 5 1 instance 5 exposed
Issued
Jan 28, 2014
Abate by
Feb 5, 2014
Penalty
Initial $5,280 · Current $5,280
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a)  191 S. Keim Street, Building 2G - On or about October 25, 2013, the electric cord used to power the overhead electrical heater at the workstation closest to the warehouse, isn't provided with strain relief at the outlet and where the electrical wire goes into heater unit.    D.W. Accor was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 908865, citation number 1, item number 12b and was affirmed as a final order on August 20, 2013, with respect to a workplace located at 191 S. Keim Street, Building 2G, Pottstown, PA.
Recent events (1)
  • · Z (R) $5280

1910.305 J01 I

Repeat Gravity 1 1 instance 3 exposed
Issued
Jan 28, 2014
Abate by
Feb 5, 2014
Penalty
Initial $2,640 · Current $2,640
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact:   a)  191 S. Keim St., Building 2G - On or about October 25, 2013, the electrical wiring of the overhead fluorescent lighting fixture, located at the front work bench, is not enclosed in approved casing, exposing employees to electrical shock.   D.W. Accor was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 908865, citation number 1, item number 11b and was affirmed as a final order on August 20, 2013, with respect to a workplace located at 191 S. Keim St., Building 2G, Pottstown, PA.
Recent events (1)
  • · Z (R) $2640

1910.141 D02 II

Repeat 1 instance 4 exposed
Issued
Jan 28, 2014
Abate by
Feb 10, 2014
Penalty
Initial $88 · Current $88
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:   a)  191 S. Keim Street, Building 2G - On or about October 25, 2013, the employer did not provide tepid water in the lavatories.  D.W. Accor was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 908865, citation number 1, item number 3a and was affirmed as a final order on August 20, 2013, with respect to a workplace located at 191 S. Keim St., Building 2G, Pottstown, PA.
Recent events (1)
  • · Z (R) $88

View D.W. Accor's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339441461.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.