PICAYUNE, MS —
OSHA Inspection: RAM MACHINE TOOLING, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAM MACHINE TOOLING, INC in 24242 RESTER ROAD, PICAYUNE, MS 39466 (NAICS 332312). OSHA activity number 339088932.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAM MACHINE TOOLING, INC
- Site address
- 24242 RESTER ROAD
- City
- PICAYUNE
- State
- MS
- ZIP
- 39466
- Mailing
- 24242 RESTER ROAD, PICAYUNE, MS 39466
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 27
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.23 C01
- Issued
- Aug 8, 2013
- Abate by
- Aug 27, 2013
- Penalty
- Initial $4,900 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: (a) 24242 Rester Rd in Picayune, MS - On or about May 23, 2013, an employee painting on top of a lower gantry 7 feet above the ground was not provided with railings or another form of fall protection.
Recent events (2)
- — I (S) $2700
- — Z (S) $4900
1910.132 A
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $2,975 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, the two different Galion hydraulic mobile cranes were missing seat belts to prevent the operator from falling out of the cab in the event of a tip over.
Recent events (2)
- — I (S) $0
- — Z (S) $2975
1910.147 C04 I
- Issued
- Aug 8, 2013
- Abate by
- Oct 25, 2013
- Penalty
- Initial $2,380 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, the employer did not have lockout/tagout procedures for specific equipment such as but not limited to air compressors, milling machines, welders, etc.
Recent events (2)
- — I (S) $1300
- — Z (S) $2380
1910.147 C06 I
- Issued
- Aug 8, 2013
- Abate by
- Oct 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, the employer had not performed any pereiodic inspections of the energy control procedures and certified that they were completed correctly.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.180 D04 X
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $2,380 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.180(d)(4)(x): Periodic inspections of mobile cranes were not performed for excessively worn or damaged tires: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, in the outside yard, a hydraulic mobile crane had severely damaged tire where the side walls were cracked and sections were missing.
Recent events (2)
- — I (S) $1300
- — Z (S) $2380
1910.180 D06
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.180(d)(6): Monthly, dated and signed inspection records and reports for wheel mounted crane(s) were not provided for critical items such as (but not limited to) brakes, crane hooks and ropes: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, in the outside yard, there were two (2) hydraulic mobile cranes that were not inspected and did not have any certified inspection records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 I09
- Issued
- Aug 8, 2013
- Penalty
- Initial $2,380 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.184(i)(9): Synthetic web sling was not immediately removed from service for having snags, cuts and tears. (a) 24242 Rester Rd in Picayune, MS - On or about May 23, 2013, a damaged synthetic web sling that was being used to handle a load.
Recent events (2)
- — I (S) $1300
- — Z (S) $2380
1910.215 A04
- Issued
- Aug 8, 2013
- Penalty
- Initial $2,380 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, in the shop building, the left tool rest on the bench grinder was 3/4 inches from the abrasive wheel.
Recent events (2)
- — I (S) $1300
- — Z (S) $2380
1910.215 B09
- Issued
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, in the shop building, the left tongue guard on the bench grinder was 1 inche from the abrasive wheel and the right tongue guard measured 1 and 3/16 inches from the abrasive wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $3,570 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, outside on the North side of the shop, the air compressor's pulleys were not guarded.
Recent events (2)
- — I (S) $1800
- — Z (S) $3570
1910.219 E01 I
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, outside on the North side of the shop, the air compressor's horizontal belts were not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Aug 8, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $1,785 · Current $900 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, in the outside area for sandblasting and spray pointing, an air nozzle used for cleaning sand blasted parts had an air pressure of 85 p. s. i..
Recent events (2)
- — I (S) $900
- — Z (S) $1785
1910.253 A03
- Issued
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(a)(3): Apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds used in an oxygen-fuel gas system had not been approved: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, in the shop building, the guage on the low pressure side of the acetylene regulator had a broken glass and was not approved to be used.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01
- Issued
- Aug 8, 2013
- Abate by
- Aug 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1): Conductors entering boxes, cabinets, or fittings were not protected from abrasions: (a) 24242 Rester Rd in Picayune, MS - On or about June 4, 2013, the conductors going into the air compressor on the outside of the shop building were exposed to abrasions and weather conditions because the motor terminal box was missing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at RAM Machine Tooling, INC
View RAM Machine Tooling, INC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339088932.