Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARTIN STEEL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARTIN STEEL, INC. in 603 16TH STREET WEST, HUNTINGTON, WV 25704 (NAICS 332312). OSHA activity number 339092447.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Martin Steel, INC. — free Get an email when a new federal OSHA severe-injury report for Martin Steel, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MARTIN STEEL, INC.
Site address
603 16TH STREET WEST
City
HUNTINGTON
State
WV
ZIP
25704
Mailing
PO BOX 7994, HUNTINGTON, WV 25704
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
32
Ownership type
A

5 citations on file for this inspection.

1910.134 E01

Repeat Gravity 1 1 instance 1 exposed
Issued
Sep 24, 2013
Abate by
Oct 11, 2013
Penalty
Initial $4,200 · Current $2,940 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:     a.  Paint/Blasting area and booth: Employees are required to wear a half face tight fitting negative pressure air purifying respirator during painting operations and a supplied air hood while metal abrasive blasting.  An employee was not provided with a medical evaluation prior to the wearing the respirators, as determined on 5/30/13.      Martin Steel, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 313372633, citation number 1, item number 1(a) and was affirmed as final order on 7/08/10, with respect to a workplace located at 603 16th Street West Huntington, WV 25704.     Abatement Certification Required For This Item.
Recent events (2)
  • — I (R) $2940
  • — Z (R) $4200

1910.134 H02 I

Repeat Gravity 5 1 instance 1 exposed
Issued
Sep 24, 2013
Abate by
Sep 30, 2013
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:      a. Paint/Blasting booth: A blasting hood/respirator used by an employee was stored hanging on a hook in the blasting booth exposed to dust and blasting media with the air supply hose lying in the abrasive dust on the floor.  The respirator was not protected from damage, contamination, or dust, as determined on 5/30/13.      Martin Steel, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(h)(2)(i), which was contained in OSHA inspection number 313372633, citation number 1, item number 1(c) and was affirmed as final order on 7/08/10, with respect to a workplace located at 603 16th Street West Huntington, WV 25704.          Abatement Certification Required For This Item.
Recent events (2)
  • — I (R) $4900
  • — Z (R) $7000

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Sep 24, 2013
Abate by
Oct 11, 2013
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a. Bay #1 Punch: Employees used a Peddinghaus 225B/20 full revolution punch #FH90 to punch holes in metal sheet.  The punch was not guarded to protect the operator or other employees in the area from the point of operation or flying chips that are being punched out of the metal, as determined on 5/30/13.    b. Bay #3 Ironworker: Employees used a Peddinghaus 110/140 Ironworker #442364660206036 to punch metal sheet.  The punch guard was damaged with a 2-1/2 inch vertical x 1-1/8 inch horizontal opening exposing the operator or employees in the area to the point of operation or flying chips punched out of the metal, as determined on 5/30/13.    c. Oster threading machine: Employees use an Oster 784 XZ-27 Pipe & Bolt machine to thread metal stock.  The rotating chuck at the rear of the machine had protruding jaws and was unguarded, as determined on 5/30/13.    Abatement Certification Required For This Item.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 24, 2013
Abate by
Oct 11, 2013
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:     a. Prep shop Cincinnati shear:  Employees used a Cincinnati 12' shear to cut metal plate that had a guard 1-3/4" to 2" above the table and within 3" of the point of operation.  The guard would not prevent employees from coming into contact with the hold downs and shear blade during operation of the shear, as determined on 5/30/13.    Abatement Certification Required For This Item.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.134 K05 II

Other-than-serious 1 instance 1 exposed
Issued
Sep 24, 2013
Abate by
Oct 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(5)(ii): Retraining was not conducted when inadequacies in the employee's knowledge or use of the respirator indicated that the employee did not retain the necessary training or skill:  a. Paint area/booth:  Retraining was not conducted for an employee in regard to respirator use in that the employee improperly stored respirators after use and used respirators with considerable growth of facial hair, as determined on 5/30/13.  Abatement Certification Required For This Item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Martin Steel, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339092447.