CORTLAND, NY ·
OSHA Inspection: PALL CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PALL CORPORATION in 3643 STATE ROUTE 281, CORTLAND, NY 13045 (NAICS 332999). OSHA activity number 339102642.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALL CORPORATION
- Site address
- 3643 STATE ROUTE 281
- City
- CORTLAND
- State
- NY
- ZIP
- 13045
- Mailing
- P.O. BOX 2030, CORTLAND, NY 13045
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 741
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Jul 19, 2013
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toe boards: a) North Building, Secondary Dispersion Tank Area, on or about 5/30/13: Open sided work platform 31-1/2 long was not provided with a standard railing, thereby exposing employees to a 14 foot 9 inch fall hazard.
Recent events (2)
- · I (S) $2975
- · Z (S) $4250
1910.147 D04 I
- Issued
- Jul 19, 2013
- Penalty
- Initial $3,400 · Current $2,380 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) North Building, Compressor Room, on or about 5/30/13: An authorized employee was performing maintenance work on the #1 Ingersoll Rand Compressor and did not affix an energy isolation device to the main electrical disconnect or air line.
Recent events (2)
- · I (S) $2380
- · Z (S) $3400
1910.147 C06 I
- Issued
- Jul 19, 2013
- Abate by
- Aug 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Pall Corporation, on or about 6/12/13: The Employer did not conduct a periodic inspection of their specific energy control procedures on an annual basis. Servicing and/or maintenance activities are performed on equipment such as but not limited to: Ingersol Rand Compressor, Poly Capper, Sidesealer, Wrapper, Shear and Spin Formers.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Jul 19, 2013
- Abate by
- Aug 23, 2013
- Penalty
- Initial $3,400 · Current $2,380 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) North Building, Water Lab, on or about 5/31/13: Killion extruder take-up roll wa not provided with guarding at the in-running points of the rollers. b) North Building, Blow Back Lab, on or about 5/31/13: Craftsman drill press was not provided with a guard to cover the serrated chuck or cutting tool. c) North Building, Blow Back Lab, on or about 5/31/13: Jet horizontal bandsaw was not provided with a guard over the unused portion of the blade. d) North Building, Machine Shop, on or about 5/31/13: Acer milling machine was not provided with a guard to cover the serrated chuck or cutting tool. e) North Building, Machine Shop, on or about 5/31/13: Manhattan drill press was not provided with a guard to cover the serrated chuck or cutting tool. f) North Building, Mechanical Lab Machine Shop, on or about 5/31/13: Jet drill press was not provided with a guard to cover the serrated chuck or cutting tool. g) North Building, Mechanical Lab Machine Shop, on or about 5/31/13: Bridgeport mill was not provided with a guard to cover the rotating chuck and cutting tool. h) North Building, Mechanical Lab, on or about 5/31/13: Jet drill press was not provided with a guard to cover the rotating chuck and cutting tool. i) Main Building, Cutoff Room, on or about 5/31/13: Kasto cutoff machines #100551 and #100552 were not adequately guarded in that the operator could reach the cutoff saw from the sides. j) 10 North Building, Warehouse Shipping Area, on or about 6/4/13: UPS conveyor belt was not provided with guarding on both sides where the belt meets the roller. k) CNC Department, on or about 6/5/13: Hardinge lathe #100654 was not provided with chuck guard. l) Manual Polish, on or about 6/5/13: Buffer #100792 was not provided with a cover over the rotating drive shaft. m) Manual Machine Shop, on or about 6/5/13: Bridgeport mill #100726 was not provided with a guard to cover the rotating chuck and cutting tool.
Recent events (2)
- · I (S) $2380
- · Z (S) $3400
1910.212 A03 II
- Issued
- Jul 19, 2013
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) North Building, Roll Mill Area, on or about 5/30/13: I2 Mill was not provided with point of operation guarding. b) Main Building, Department 13, on or about 5/31/13: Accurshear #100376 was not provided with adequate guarding in that the operator could reach the point of operation while hand feeding material into the shear.
Recent events (2)
- · I (S) $2975
- · Z (S) $4250
1910.215 B09
- Issued
- Jul 19, 2013
- Penalty
- Initial $2,550 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) North Building, Blow Back Lab, on or about 5/31/13: Delta grinder was not provided with an adjustable tongue guard at the top and the distance between the abrasive wheel and the end of the safety guard peripheral member at the top measured 1-inch.
Recent events (2)
- · I (S) $1785
- · Z (S) $2550
More inspections at Pall Corporation
View Pall Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339102642.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.