Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WBE WALLS & CEILINGS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WBE WALLS & CEILINGS, INC. in 765 ELMWOOD AVENUE, BUFFALO, NY 14222 (NAICS 238310). OSHA activity number 339102683.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch WBE Walls & Ceilings, INC. — free Get an email when a new federal OSHA severe-injury report for WBE Walls & Ceilings, INC. is published. One employer, no account, unsubscribe in one click.
Site address
765 ELMWOOD AVENUE
City
BUFFALO
State
NY
ZIP
14222
Mailing
195 INDUSTRIAL DRIVE, SUITE 206, GRAND ISLAND, NY 14072
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.451 E06 VI

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 21, 2013
Penalty
Initial $1,020 · Current $800 Reduced
29 CFR 1926.451(e)(6)(vi):  Integral prefabricated scaffold access frames did not have a maximum spacing between rungs of 16 3/4 inches (43 cm):        a) On or about 6/05/13 on construction site of a building under renovation at 765 Elmwood Ave., Buffalo, NY: An employee climbed the end frame of the fabricated frame mobile scaffold to access a single aluminum "pik" setting on the bottom horizontal member on the third frame up. The spacing between the rungs was 20 inches.           NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $800
  • — C (S) $1020
  • — Z (S) $1020

1926.451 G01 VII

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jun 21, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    a) On or about 6/05/13 on construction site of a building under renovation at 765 Elmwood Ave., Buffalo, NY: An employee was standing on a single aluminum "pik" setting on the bottom horizontal member on the third frame up, on a fabricated frame mobile scaffold. The employee was assisting his foreman who was on the roof plumbing up a steel stud. The employee was exposed to a fall of approx. 12 ft. 7 in. off the backside (north side) of the "pik" because no guardrails or other fall protection system was installed to protect the employee.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $1600
  • — Z (S) $1600

1926.451 B01 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jun 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.    a) On or about 6/05/13 on construction site of a building under renovation at 765 Elmwood Ave., Buffalo, NY: An employee was standing on a single aluminum "pik" setting on the bottom horizontal member on the third frame up, on a fabricated frame mobile scaffold. The employee was assisting his foreman who was on the roof plumbing up a steel stud. The work level was approx. 60 in. wide between the inside & outside uprights and the single "pik" was approx. 20 in. wide.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Jun 21, 2013
Penalty
Initial $80 · Current $0 Reduced
WBE WALLS & CEILINGS, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 903567, CITATION NO. 1, ITEM NO. 1, AND WAS AFFIRMED AS A FINAL ORDER ISSUED ON 06/13/2013, WITH RESPECT TO A WORKPLACE LOCATED AT 4460 CHESTNUT RIDGE ROAD, AMHERST, NY 14226.      29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:         a) On or about 6/05/13 on construction site of a building under renovation at 765 Elmwood Ave., Buffalo, NY: A DeWalt 14" Chop Saw used to cut steel studs was connected to 120-volt ac power via a series of two extension cords. The second extension cord (red ext. cord) in the series lacked a grounding prong on its' plug.       NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (O) $0
  • — C (R) $80
  • — Z (R) $80

View WBE Walls & Ceilings, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339102683.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.