Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: YES EQUIPMENT & SERVICES, INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of YES EQUIPMENT & SERVICES, INC. in W136 N4901 CAMPBELL DR., MENOMONEE FALLS, WI 53052 (NAICS 811310). OSHA activity number 339107203.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch YES Equipment & Services, INC. — free Get an email when a new federal OSHA severe-injury report for YES Equipment & Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
W136 N4901 CAMPBELL DR.
City
MENOMONEE FALLS
State
WI
ZIP
53052
Mailing
W136 N4901 CAMPBELL, MENOMONEE FALLS, WI 53052
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
81
Ownership type
A

4 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2013
Abate by
Oct 17, 2013
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    (a)  The employer did not ensure that employees who accessed the mezzanine level to change out soap totes or perform minor servicing work were protected from falling to the lower level by the use of standard guard railings or an equivalent form of fall protection.
Recent events (3)
  • — F (S) $1800
  • — C (S) $2800
  • — Z (S) $2800

1910.147 D

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 27, 2013
Abate by
Oct 4, 2013
Penalty
Initial $3,500 · Current $3,500
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    (a)  The employer did not ensure that authorized employees affixed locks and tags on all energy sources to render it fully inoperative prior to maintenance/servicing on equipment such as but not limited to Yale fork trucks.
Recent events (3)
  • — F (S) $3500
  • — C (S) $3500
  • — Z (S) $3500

1910.147 C04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 27, 2013
Abate by
Oct 17, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a)  The employer did not develop and document energy control procedures that were specific to the equipment employees performed maintenance/servicing on, such as but not limited to Yale fork trucks or the air compressor.       YES Equipment & Services, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard [29 CFR 1910.147(c)(4)(i)], which was contained in OSHA inspection number 721501, citation number 1, item number 2 and was affirmed as a final order on March 8, 2013, with respect to a workplace located at W136 N4901 Campbell Drive, Menomonee Falls, Wisconsin.
Recent events (3)
  • — F (S) $0
  • — C (R) $7000
  • — Z (R) $7000

1910.22 D01

Other-than-serious 1 instance 2 exposed
Issued
Sep 27, 2013
Abate by
Oct 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  (a)  The employer did not ensure that the mezzanine containing the air compressor was marked with a load rating plate.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View YES Equipment & Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339107203.