Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: J. D. ECKMAN INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J. D. ECKMAN INCORPORATED in 1038 DUKE STREET, LANCASTER, PA 17601 (NAICS 237110). OSHA activity number 339110082.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J. D. Eckman Incorporated for free Get an email when a new federal OSHA severe-injury report for J. D. Eckman Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1038 DUKE STREET
City
LANCASTER
State
PA
ZIP
17601
Mailing
4781 LOWER VALLEY RD P.O. BOX 160, ATGLEN, PA 19310
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
500
Ownership type
Private (A)

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 19, 2013
Penalty
Initial $5,500 · Current $4,125 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  (a) 1038 Duke Street Lancaster, PA - An employee working in a trench greater than 4 feet deep did not have access to a ladder or safe means of egress from his location in the trench, on or about June 11, 2013.   No abatement certification or documentation required.
Recent events (2)
  • · I (S) $4125
  • · Z (S) $5500

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 19, 2013
Penalty
Initial $5,500 · Current $4,125 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  (a) 1038 Duke Street Lancaster, PA - An employee working in a trench greater than 5 feet deep and was not protected from a cave-in, on or about June 11, 2013.   No abatement certification or documentation required.
Recent events (2)
  • · I (S) $4125
  • · Z (S) $5500

View J. D. Eckman Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339110082.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.