DORAVILLE, GA —
OSHA Inspection: SCHUTZ CONTAINER SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SCHUTZ CONTAINER SYSTEMS, INC. in 2150-F BUTTON GWINNETT DRIVE, DORAVILLE, GA 30340 (NAICS 322214). OSHA activity number 339111130.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCHUTZ CONTAINER SYSTEMS, INC.
- Site address
- 2150-F BUTTON GWINNETT DRIVE
- City
- DORAVILLE
- State
- GA
- ZIP
- 30340
- Mailing
- 2150-F BUTTON GWINNETT DRIVE, DORAVILLE, GA 30340
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322214
- Employees
- 101
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Sep 11, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $4,125 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. On or about June 11, 2013, employees were exposed to dust hazards when dust from the polyethylene grinding operation in the grinding room was visible up to approximately one inch thick on the equipment and walls.
Recent events (2)
- — I (S) $2475
- — Z (S) $4125
1910.146 C02
- Issued
- Sep 11, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $2,475 · Current $1,485 Reduced
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: On or about June 11, 2013, employees were exposed to engulfment hazards when the silos were missing confined space signs.
Recent events (2)
- — I (S) $1485
- — Z (S) $2475
1910.147 C04 II
- Issued
- Sep 11, 2013
- Abate by
- Oct 29, 2013
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: On or about June 11, 2013, employees were exposed to hazards when the lockout/tagout procedures did not include steps to verify that the equipment was de-energized, steps to return power to the equipment, information about the type and magnitude of the energy sources, and how to lockout the equipment when performing setup or cleaning instead of maintenance.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.147 C06 I
- Issued
- Sep 11, 2013
- Abate by
- Oct 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: On or about June 11, 2013, employees were exposed to struck-by hazards when the lockout/tagout procedures had not been inspected to insure that all required elements were included in the procedures, that the procedures were correct and being followed, and that all authorized and affected employees knew their responsibilities when involved in equipment lockout/tagout.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 N06
- Issued
- Sep 11, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.178(n)(6): Industrial truck drivers were not required to look in the direction of, and keep a clear view of the path of travel: On or about June 12, employees were exposed to struck-by hazards when forklift drivers did not drive backward when the load of totes being transported was too tall to see over.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
More inspections at Schutz Container Systems, INC.
View Schutz Container Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322214)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339111130.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.