SAYVILLE, NY —
OSHA Inspection: CARY INSULATION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CARY INSULATION in 135 LAKELAND AVE., SAYVILLE, NY 11782 (NAICS 238990). OSHA activity number 339114225.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARY INSULATION
- Site address
- 135 LAKELAND AVE.
- City
- SAYVILLE
- State
- NY
- ZIP
- 11782
- Mailing
- 165 ORVILLE DRIVE, BOHEMIA, NY 11716
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 27, 2013
- Abate by
- Dec 4, 2013
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: Worksite, 129 Lakeland Ave. Sayville NY - Employee was walking and working on the top of a foundation wall measuring approximately 10ft-15ft above the ground below. The employee was not provided with fall protection; on or about 6/12/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1926.651 C02
- Issued
- Nov 27, 2013
- Abate by
- Dec 4, 2013
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Worksite, 129 Lakeland Ave. Sayville NY - Employees were working in an excavation approximately 10ft - 15ft deep and were not provided with a safe means of egress; on or about 6/12/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $2450
- — Z (S) $3500
1926.651 J02
- Issued
- Nov 27, 2013
- Abate by
- Dec 4, 2013
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) Worksite, 129 Lakeland Ave. Sayville NY - Spoil piles, concrete forms, and other scattered construction material were placed on the edge of the excavation; on or about 6/12/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $2450
- — Z (S) $3500
1926.701 B
- Issued
- Nov 27, 2013
- Abate by
- Dec 4, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a) Worksite, 129 Lakeland Ave. Sayville NY - Employee was walking and working on the top of a foundation wall, above uncapped rebar; on or about 6/12/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B01
- Issued
- Nov 27, 2013
- Abate by
- Dec 4, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Worksite, 129 Lakeland Ave. Sayville NY - Employee was accessing the top of a foundation wall by using an extension ladder that was set up below the landing; on or about 06/12/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
More inspections at Cary Insulation
View Cary Insulation's full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339114225.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.