CARTERSVILLE, GA —
OSHA Inspection: HEATCO INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HEATCO INC in 50 HEATCO COURT, CARTERSVILLE, GA 30120 (NAICS 332410). OSHA activity number 339114639.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEATCO INC
- Site address
- 50 HEATCO COURT
- City
- CARTERSVILLE
- State
- GA
- ZIP
- 30120
- Mailing
- 50 HEATCO COURT, CARTERSVILLE, GA 30120
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332410
- Employees
- 48
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Aug 16, 2013
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specify procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) In the Production Area, adequate specific procedures for shutting down, isolating and securing energy sources were not developed by the employer to ensure employees were not exposed to electrical and crushed-by hazards when servicing equipment such as, but not limited to, the turbulator and swage machines.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.147 C06 I
- Issued
- Aug 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) In the Production Area, the employer did not conduct periodic inspections of energy control procedures to ensure that adequate procedures were being utilized for maintenance and servicing of equipment such as, but not limited to, the laser cutter, turbulator and swage machines, exposing employees to electrical, crushed-by and amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Aug 16, 2013
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) In the Production Area, authorized and affected employees operating and servicing equipment such as, but not limited to, the laser cutter, turbulator and swage machines were not provided with training to ensure the employees understood the purpose and the function of the Company's energy control procedures. The employees were exposed to electrical, crushed-by and amputation hazards.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
More inspections at Heatco INC
View Heatco INC's full OSHA safety record →
More inspections in this industry (NAICS 332410)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339114639.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.