ROCKFORD, IL —
OSHA Inspection: AREA ROOFING & RENOVATIONS LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AREA ROOFING & RENOVATIONS LLC in AUBURN ST. AND AVON ST., ROCKFORD, IL 61101 (NAICS 238160). OSHA activity number 339115107.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AREA ROOFING & RENOVATIONS LLC
- Site address
- AUBURN ST. AND AVON ST.
- City
- ROCKFORD
- State
- IL
- ZIP
- 61101
- Mailing
- 4204 SHOREWOOD DRIVE, ROCKFORD, IL 61101
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.416 A01
- Issued
- Jun 20, 2013
- Abate by
- Jul 17, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: At a jobsite in Rockford, Illinois employees working on a flat commercial roof were exposed to electrical hazards from a 220V drop that extended to the facility's roof.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.451 E01
- Issued
- Jun 20, 2013
- Abate by
- Jul 17, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Employees working from a ladder jack scaffold approximately 12 feet above grade were not using a method of safe access/egress. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.451 G01
- Issued
- Jun 20, 2013
- Abate by
- Jul 17, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: Employees working from the platform of a ladder jack scaffold approximately 12 feet above grade were not using any method of fall protection. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.501 B01
- Issued
- Jun 20, 2013
- Abate by
- Jul 17, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. An employee working from a flat commercial roof approximately 19 feet above grade installing a facia board was not using any method of fall protection. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections at Area Roofing & Renovations LLC
View Area Roofing & Renovations LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339115107.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.