SHAW A F B, SC ·
OSHA Inspection: C.W. RESOURCES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of C.W. RESOURCES, INC. in 250 AIKEN STREET BLDG. 26, SHAW A F B, SC 29152 (NAICS 561730). OSHA activity number 339115784.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C.W. RESOURCES, INC.
- Site address
- 250 AIKEN STREET BLDG. 26
- City
- SHAW A F B
- State
- SC
- ZIP
- 29152
- Mailing
- 200 MYRTLE STREET, NEW BRITAIN, CT 06053
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- Employees
- 15
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
1910.95 C01
- Issued
- Nov 13, 2013
- Abate by
- Dec 8, 2013
- Penalty
- Initial $4,000 · Current $4,000
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: (a) On 6/13/13, three employees were determined to be exposed to noise in excess of an 8-hour time-weighted average sound level of 85 decibels while operating gas-powered mowers, trimmers, and blowers. The employer had not administered a continuing, effective hearing conservation program. The elements of hearing conservation program include the following: * Developing and implementing a noise monitoring program * Establishing and maintaining an audiometric testing program * Making hearing protection available for employees to wear and giving them the opportunity to select their hearing protection from a variety of hearing protectors (e.g., muffs or plugs). * Instituting a noise training program * Providing employees with a copy of noise standard * Maintaining records of noise monitoring and audiometric testing
Recent events (1)
- · Z (S) $4000
1910.132 A
- Issued
- Nov 13, 2013
- Abate by
- Nov 21, 2013
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used and maintained in a reliable condition when necessary whenever hazards capable of causing injury and impairment were encountered: (a) Adjacent to Child Development Center: An employee operating a ZD 331 Kubota riding mower equipped with a rollover protection structure (ROPS) was observed not wearing the seat belt provided. The seat belt could not be worn due to a defective latch. (b) Adjacent to Child Development Center: An employee operating a ZD 331 Kubota riding mower equipped with a rollover protection structure (ROPS) was observed not wearing the seat belt provided. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- · Z (S) $5000
1910.212 B
- Issued
- Nov 13, 2013
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) A Delta Shopmaster bench grinder stationed on a work bench adjacent to the west wall of the Shop was not anchored down.
Recent events (1)
- · Z (S) $3000
1910.215 A04
- Issued
- Nov 13, 2013
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) The work rest of a Delta Shopmaster bench grinder stationed on a work bench adjacent to the west wall of the Shop was adjusted to approximately one half inch from the abrasive grinding wheel.
Recent events (1)
- · Z (S) $3000
1910.215 B09
- Issued
- Nov 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. a) A Delta Shopmaster bench grinder stationed on a work bench adjacent to the west wall of the Shop was not equipped with a tongue guard over the left-hand side abrasive wheel. There was a gap of 1-inch between the abrasive wheel and the peripheral member.
Recent events (1)
- · Z (S) $0
1910.253 B02 II
- Issued
- Nov 13, 2013
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: (a) A compressed cylinder of acetylene and oxygen were being stored together upright and unsecured adjacent to an exit door on the west side of Building 26. The cylinders could be knocked over or damaged by passing personnel or equipment or subject to tampering by unauthorized persons.
Recent events (1)
- · Z (S) $3000
1910.305 G01 IV
- Issued
- Nov 13, 2013
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): (a) West side of Building 26: Approximatley 5 extension cords (carrying 120 volts) were used in lieu of fixed wiring to provide power to such equipment as a parts washer, pedestal fan, lights, drill, press, bench grinder, and portable grinder. (b) West wall of Building 26: Two orange extension cords which were plugged into a power strip inside the building were run outside through a cut out hole in the metal wall of the building adjacent to an exterior door. One of the extension cords was being used at a workbench to power handheld equipment (e.g., grinder). The other extension cord extended along the foundation of the building and re-entered the building through a crack between the metal siding and the concrete foundation. (c) West wall of Buildilng 26: An orange extension cord and a cable to a power strip which the extension cord was plugged into were attached to the metal frame of the building with zip ties. (d) West side of Building 26: A yellow extension cord which supplied power to a drill press was attached to a metal fence and steel building structures.
Recent events (1)
- · Z (S) $5000
1910.1200 E01
- Issued
- Nov 13, 2013
- Abate by
- Dec 8, 2013
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) The employer did not develop, fully implement, or maintain a written hazard communication program at the workplace where employees were potentially exposed to such hazardous chemicals as welding gases, mineral spirits, grease, engine oil, diesel fuel, and gasoline. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- · Z (S) $3000
1910.1200 H01
- Issued
- Nov 13, 2013
- Abate by
- Dec 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(2) and (h)(3) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Employees who was exposed to hazardous chemicals during grass trimming, mowing and equipment maintenance had not been provided information and training concerning the following: * Information concerning the requirements of the hazard communication standard * Information regarding the location and availability of the written hazard communication program and the required list of hazardous chemicals * Training on the physical and health hazards of chemicals * Training on the details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by the employer ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- · Z (S) $0
1910.134 K06
- Issued
- Nov 13, 2013
- Abate by
- Nov 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) At least two employees who wore disposable filtering facepiece respirators on a voluntary basis while performing landscaping activities had not been provided with the basic advisory information on respirators, as presented in Appendix D. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- · Z (O) $0
1910.157 E03
- Issued
- Nov 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) A portable ABC fire extinguisher mounted on the wall inside the office adjacent to the exit door was last inspected in August 2011. (b) A portable ABC fire extinguisher mounted near a rollup door on the north wall of Building 26 was last inspected in August 2011. (c) A portable ABC fire extinguisher mounted on the west wall of Building 26 was last inspected in July 2008. (d) A portable ABC fire extinguisher mounted on the east wall of Building 26 was last inspected in August 2011. (e) A portable ABC fire extinguisher mounted on the south wall of Building 26 was discharged and had not received an annual inspection.
Recent events (1)
- · Z (O) $0
More inspections at C.W. Resources, INC.
View C.W. Resources, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561730)
More inspections in SC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339115784.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.