MOUNTAIN CENTER, CA ·
OSHA Inspection: USDA FOREST SERVICE - SAN BERNARDINO NF
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of USDA FOREST SERVICE - SAN BERNARDINO NF in 28500 HIGHWAY 243 KEENWILD STATION, MOUNTAIN CENTER, CA 92561 (NAICS 922160). OSHA activity number 339119125.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- USDA FOREST SERVICE - SAN BERNARDINO NF
- Site address
- 28500 HIGHWAY 243 KEENWILD STATION
- City
- MOUNTAIN CENTER
- State
- CA
- ZIP
- 92561
- Mailing
- 602 S. TIPPECANOE AVE, SAN BERNARDINO, CA 92408
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922160
- Employees
- 8
- Ownership type
- Federal government (D)
Citations
11 citations on file for this inspection.
1910.23 C01
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Engine Bay Loft: On or about 06JUN13, employees were exposed to fall hazards where a 14 inch gap was present between the stair railing and fencing on an open sided platform nine feet above the lower level.
Recent events (1)
- · Z (S) $0
1910.212 A01
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Engine Bay: On or about 06JUN13, a drill press lacked a method of machine guarding to protect employees from flying chips and sparks.
Recent events (1)
- · Z (S) $0
1910.213 B03
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: Engine Bay: On or about 06JUN13, a drill press lacked a method to prevent the drill from automatically restarting upon restoration of power after power failure.
Recent events (1)
- · Z (S) $0
1910.215 A04
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Engine Bay: On or about 06JUN13, a bench grinder was used without the work rest adjusted to within one eighth inch of the wheel surface.
Recent events (1)
- · Z (S) $0
1910.215 B09
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Exposure adjustment: Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.) Engine Bay: On or about 06JUN13, a bench grinder was used without the tongue guard adjusted to within one quarter inch of the wheel surface.
Recent events (1)
- · Z (S) $0
1910.242 B
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Engine Bay: On or about 06JUN13, a portable air compressor used by the employees for cleaning was not reduced to less than 30 p.s.i. and the use of eye protection was not enforced.
Recent events (1)
- · Z (S) $0
1910.253 B04 I
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: Gas House: On or about 06JUN13, a compressed gas cylinder containing oxygen was stored with acetylene gas cylinders, containers of gasoline, and various oils and petroleum-based solvents.
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Engine Bay: On or about 06JUN13, a power strip connected in series to an extension cord to provide 120VAC electrical service to a refrigerator.
Recent events (1)
- · Z (S) $0
1910.303 B07 I
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: Engine Bay Loft: On or about 06JUN13, 120VAC live conductors were exposed to inadvertent employee contact where an opening in a light switch cover was left open.
Recent events (1)
- · Z (S) $0
1910.305 G01 IV A
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: Engine Bay: On or about 06JUN13, a flexible cord were used to provide 120VAC service to a refrigerator.
Recent events (1)
- · Z (S) $0
1910.334 A02 II
- Issued
- Jul 11, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made. Engine Bay: On or about 06JUN13, the flexible cord insulation of a portable cut-off saw was badly dry-rotted exposing the conductors of the cord, exposing employees to electrical shock.
Recent events (1)
- · Z (S) $0
More inspections at Usda Forest Service - SAN Bernardino NF
View Usda Forest Service - SAN Bernardino NF's full OSHA safety record →
More inspections in this industry (NAICS 922160)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339119125.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.