EAST STROUDSBURG, PA —
OSHA Inspection: ADVANCED DOOR TECHNOLOGIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADVANCED DOOR TECHNOLOGIES, INC. in 34 NORTH CRYSTAL ST, EAST STROUDSBURG, PA 18301 (NAICS 332322). OSHA activity number 339124349.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED DOOR TECHNOLOGIES, INC.
- Site address
- 34 NORTH CRYSTAL ST
- City
- EAST STROUDSBURG
- State
- PA
- ZIP
- 18301
- Mailing
- 34 NORTH CRYSTAL STREET, EAST STROUDSBURG, PA 18301
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 45
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 L04 III
- Issued
- Jul 3, 2013
- Abate by
- Jul 19, 2013
- Penalty
- Initial $3,570 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) At Advanced Door Technologies, located at 34 North Crystal Street, East Stroudsburg, PA 18301: An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years. Employees were exposed to motor vehicle hazards on or about June 18, 2013. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (S) $2500
- — Z (S) $3570
1910.178 L06
- Issued
- Jul 3, 2013
- Abate by
- Jul 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) At Advanced Door Technologies, located at 34 North Crystal Street, East Stroudsburg, PA 18301: The employer did not certify that each forklift operator has been trained and evaluated. Employees were exposed to motor vehicle hazards on or about June 18, 2013. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- Jul 3, 2013
- Abate by
- Jul 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). (a) At Advanced Door Technologies, located at 34 North Crystal Street, East Stroudsburg, PA 18301: Employees were operating a defective propane forklift--model number TCO 520/TCM--which had a metal bar protruding from the seat. The tires on this forklift were noticibly worn out. Employees were exposed to powered industrial truck hazards which may result in physical injury on or about June 18, 2013. (b) At Advanced Door Technologies, located at 34 North Crystal Street, East Stroudsburg, PA 18301: Employees were operating a defective propane forklift--model number ECG25/TCM--which had tires that were visibly worn out. Employees were exposed to powered industrial truck hazards which may result in physical injury on or about June 18, 2013 In accordance with with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Jul 3, 2013
- Abate by
- Jul 24, 2013
- Penalty
- Initial $2,975 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) At Advanced Door Technologies, 34 North Crystal Street, East Stroudsburg, PA 18301, in the Steel Angle Area: There were two (2) drill presses, two (2) Ironworkers, and an overhead crane which were serviced by the Maintenance Manager without following an established LO/TO program consisting of an energy control procedure, employee training and periodic inspections. Employees were exposed to industrial machines that could unexpectedly energize, startup, or release stored energy resulting in possible personal injury and/or death, on or about June 18, 2013. In accordance with 29 CFR 1903.19(c), abatement certification and documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $2975
More inspections at Advanced Door Technologies, INC.
View Advanced Door Technologies, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in PA
Source