OSHA Inspection: ADVANCED DOOR TECHNOLOGIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ADVANCED DOOR TECHNOLOGIES, INC. in 34 NORTH CRYSTAL STREET, EAST STROUDSBURG, PA 18301 (NAICS 332322). OSHA activity number 339126674.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Door Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Advanced Door Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
34 NORTH CRYSTAL STREET
City
EAST STROUDSBURG
State
PA
ZIP
18301
Mailing
34 NORTH CRYSTAL STREET, EAST STROUDSBURG, PA 18301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
45
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 5, 2013
Abate by
Dec 8, 2013
Penalty
Initial $2,100 · Current $2,100

Hazardous substances 1073108024602590

29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer:  a) Advanced Door Technologies:  Employees were required to wear respirators and the employer did not establish/implement a written respiratory protection program, on or about 06/26/2013.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2100

1910.134 E01

Serious Gravity 1 2 instances 2 exposed
Issued
Nov 5, 2013
Abate by
Dec 8, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1073108024602590

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Spray Booth Area:  An employee, painter, was required to wear a half-mask elastomeric respirator while painting door tracks and the employee was not provided with a medical evaluation prior to donning the respirator, on or about 06/26/2013.  b) Insulating Area:  An employee, insulator, was required to wear a half-mask elastomeric respirator while insulating door tracks and the employee was not provided with a medical evaluation prior to donning the respirator, on or about 06/26/2013.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 2 instances 2 exposed
Issued
Nov 5, 2013
Abate by
Dec 8, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1073108024602590

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator, whenever a different respirator facepiece is used, and at least annually thereafter.  a) Spray Booth Area:  An employee, painter, was required to wear a half-mask elastomeric respirator while painting door tracks and the employee was not provided with an annual respirator fit test, on or about 06/26/2013.  b) Insulating Area:  An employee, insulator, was required to wear a half-mask elastomeric respirator while insulating door tracks and the employee was not provided with an annual respirator fit test, on or about 06/26/2013.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.134 K03

Serious Gravity 1 2 instances 2 exposed
Issued
Nov 5, 2013
Abate by
Dec 8, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1073108024602590

29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  a) Spray Booth Area:  An employee, painter, was required to wear a half-mask elastomeric respirator while painting door tracks and the employee was not provided with annual respirator training, on or about 06/26/2013.  b) Insulating Area:  An employee, insulator, was required to wear a half-mask elastomeric respirator while insulating door tracks and the employee was not provided with annual respirator training, on or about 06/26/2013.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.107 E02

Other-than-serious 1 instance 1 exposed
Issued
Nov 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift.  a) Paint Booth Area:  Employees were exposed to a fire hazard when flammable paints (Sherwin Williams - Quick Dry Enamel) were stored directly outside the doors of the spray booth in a quantity greater than one days use, on or about 06/18/2013.  ABATED DURING INSPECTION  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (O) $0

View Advanced Door Technologies, INC.'s full OSHA safety record →