NEWARK, NJ —
OSHA Inspection: ROYAL ALUMINUM CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ROYAL ALUMINUM CO., INC. in 620 MARKET STREET, NEWARK, NJ 07105 (NAICS 326199). OSHA activity number 339124471.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROYAL ALUMINUM CO., INC.
- Site address
- 620 MARKET STREET
- City
- NEWARK
- State
- NJ
- ZIP
- 07105
- Mailing
- 620 MARKET STREET, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 65
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.26 C03 VII
- Issued
- Aug 14, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.26(c)(3)(vii): Ladders were used as a brace, skid, guy or gin pole, gangway, or for other uses than that for which they were intended, unless specifically recommended for use by the manufacturer: a. 620 Market Street, Newark, NJ - Vinyl Area, access to second level storage The employer erected an aluminum A-frame ladder in a manner for other than which it was intended by the manufacturer. The ladder was used in the closed position by employees as access to the second story storage area. Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.37 A03
- Issued
- Aug 14, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a. 620 Market Street, Newark, NJ - Exit to Somme Street NW corner Emergency exit routes were not kept unobstructed for use by employees. The emergency exit door was blocked using a screen and a chair, preventing free egress. Violation observed on or about June 19, 2013 b. 620 Market Street, Newark, NJ - Exit to rear of building South side Emergency exit routs were not kept unobstructed for use by employees. The exit route from the Vinyl area to the rear door, and the exit rout from the Casements area were reduced to less than 28 inches from placement of materials stored in the exit route. Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.37 B04
- Issued
- Aug 14, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a. 620 Market Street, Newark, NJ - Storm Windows Area, Casements Area, Metal Frames Area Directional signs were not posted along the exit access in the production area. Direction of travel to the emergency exit discharge were not immediately apparent where the signs were obstructed from view in the Vinyl area to the exit, and direction to the exits were not immediately identifiable throughout the Casements, Metal Frame, and Strom Window areas. Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.37 B05
- Issued
- Aug 14, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a. 620 Market Street, Newark, NJ - Boiler Room area Doorways along the exit routes that could be mistaken as an exit were not marked "Not an Exit". The doorway into the boiler room could have been mistaken as an emergency exit and was not a usable exit in the event of an emergency. Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.106 E06 II
- Issued
- Aug 14, 2013
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii):Category 1 flammable liquids with a flashpoint below 100 °F (37.8°C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected, where the fill stem is bonded to the container during filling operations by means of a bond wire. a. 620 Market Street, Newark, NJ - Vinyl Area, Toluene dispensing area Clategory 1 flammable liquids, which included, but was not limited to Toluene, was dispensed into portable containers which were not electrically interconnected or bonded to the dispensing nozzle. Employees dispensed Toluene from a 55-gallon storage container using a hand pump that was not bonded/grounded to the portable container at the time of dispensing. Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.133 A01
- Issued
- Aug 14, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation a. 620 Market Street, Newark, NJ - Storm Window Area The employer did not ensure his employees used appropriate eye protection from flying particles when operating a pneumatic drill. An employee drilling into window frames was not protected by use of eye or face protection when operating a pneumatic drill. Violation was observed on or about June 19, 2013
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.178 A05
- Issued
- Aug 14, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a. 620 Market Street, Newark, NJ and 59-53 Somme Street, Newark, NJ The Toyota forklift with a front-end attachment was not marked to identify the attachments and show the approximate weight of the truck and attachment combination. The Toyota forklift used to move vinyl and aluminum materials from the storage warehouse to the production area was not marked to identify the combination weight of the attachment and forklift at maximum elevation. Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.178 O02
- Issued
- Aug 14, 2013
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.178(o)(2): Load(s) were being handled which exceeded the rated capacity of the industrial truck(s): a. 620 Market Street and 59-53 Somme Street, Newark, NJ - Storage warehouse to loading docks. Materials being handled using a Toyota model 7FGCU25 powered industrial truck exceeded the rated capacity of the industrial truck per the manufacturers placard with the boom attachment. Violation observed on or about July 24, 2013
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.178 Q01
- Issued
- Aug 14, 2013
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: a. 620 Market Street, Newark, NJ - Shipping Area, east end of building. The powered industrial truck (forklift) was not in a safe operating condition. The Toyota forklift used in the shipping area (serial number 60149) was not taken out of service and repairs were not made for the attachment of the propane fuel cylinder. Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1910.305 A02 I
- Issued
- Aug 14, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installations rated 600 volts, nominal, or less were used for purposes other than those permitted in subparagraphs (A), (B) and (C) of this paragraph. a. 620 Market Street, Newark, NJ - Men's restroom The electrical lighting installation was not used in a manner specified by the manufacturer. Non-metallic sheathed electrical cable (Romex®) wiring was used a permanent wiring on the exterior of the wall in the employees' bathroom (mens). Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.305 B01 II
- Issued
- Aug 14, 2013
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. 59-53 Somme Street, Newark, NJ The electrical circuit breaker panel (cabinet) for interior lights circuit breakers did not have effectively closed openings. The circuit breaker panel had the knockouts missing to more than half of the openings where there were not circuit breakers. Violation observed on or about July 23, 2013
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.305 B02 I
- Issued
- Aug 14, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose. a. 620 Market Street, Newark, NJ - production area men's bathroom The light switch cover in the men's bathroom was broken at the corner and did not provide protection to employees from electrical shock hazards. Violation observed on or about June 19, 2013
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
More inspections at Royal Aluminum CO., INC.
View Royal Aluminum CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339124471.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.