BROKEN ARROW, OK —
OSHA Inspection: BROKEN ARROW POWDER COATING, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of BROKEN ARROW POWDER COATING, INC. in 809 N. 16TH STREET, BROKEN ARROW, OK 74012 (NAICS 332812). OSHA activity number 339126229.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BROKEN ARROW POWDER COATING, INC.
- Site address
- 809 N. 16TH STREET
- City
- BROKEN ARROW
- State
- OK
- ZIP
- 74012
- Mailing
- 809 N. 16TH STREET, BROKEN ARROW, OK 74012
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 5
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.24 F
- Issued
- Nov 13, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $1,200 · Current $500 Reduced
General-duty citation text
29 CFR 1910.24(f): All treads were not reasonably slip-resistant and the nosings were not of nonslip finish and rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of stairs: a. On or about 6/18/2013, Shop, Slip resistant stair treads and uniform riser height were not provided at stairs attached to the east and west openings of the spray booth thereby exposing employees slip hazards.
Recent events (2)
- — I (S) $500
- — Z (S) $1200
1910.24 H
- Issued
- Nov 13, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: a. On or about 6/18/2013, Shop, stair railings were not provided at stairs attached to the east and west openings of the spray booth thereby exposing employees slip hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.94 C06 I
- Issued
- Nov 13, 2013
- Abate by
- Dec 20, 2013
- Penalty
- Initial $1,600 · Current $650 Reduced
2440T405
General-duty citation text
29 CFR 1910.94(c)(6)(i): The velocity of air into all openings of a spray booth was less than that specified in Table G-10 for the operating conditions specified: a. On or about 6/19/2013, Shop, the air velocity through the east spray booth opening was less than 75 feet per minute during manual electrostatic powder spraying operations which exposes employees to hazardous substances.
Recent events (2)
- — I (S) $650
- — Z (S) $1600
1910.1000 A02
- Issued
- Nov 13, 2013
- Abate by
- Dec 20, 2013
- Penalty
- Initial $0 · Current $0
2440T405
General-duty citation text
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Titanium Dioxide Total Dust listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 15 mg/m3: a. On or about 6/19/2013, in the Shop, an employee's personal 8-hour time-weighted average (8-Hr TWA) exposure to Total Dust containing Titanium Dioxide and Triglycidyl Isocyanurate was 160.0 mg/m3 during electrostatic hand spraying of powder coatings. This exposure exceeded the OSHA 8-Hr TWA total dust PEL of 15 mg/m3 by 10.8 times. The personal air monitoring consisted of four samples collected during a 417 minute sampling period on 6/19/2013. The remaining un-sampled time of 63 minutes was included in the 8-Hr TWA as a zero exposure period.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1000 E
- Issued
- Nov 13, 2013
- Abate by
- Dec 20, 2013
- Penalty
- Initial $0 · Current $0
2440T405
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a. On or about 6/19/2013, Shop, feasible administrative or engineering controls which includes but is not limited to the following, were not implemented for electrostatic hand spraying of powder coatings which exposes employees to hazardous substances: 1. Spray towards the mechanical exhaust hood openings 2. Transfer powders to containers inside the ventilated spray booth 3. Replace dry sweeping with HEPA filtered vacuums listed for combustible dust use 4. Rotate daily powder spray coating tasks among different employees
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B05 I
- Issued
- Nov 13, 2013
- Abate by
- Dec 20, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
2440T405
General-duty citation text
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained: a. On or about 6/18/2013, Shop, the spray booth lacked visible gauges or audible alarm or pressure activated devices to indicate or insure that required air velocity was maintained during manual electrostatic powder spraying which exposes employees to combustible dust hazards.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.107 B05 IV
- Issued
- Nov 13, 2013
- Abate by
- Dec 20, 2013
- Penalty
- Initial $0 · Current $0
2440T405
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a. On or about 6/18/2013, Shop, the spray booth was not protected with approved automatic sprinklers or an automatic fire extinguishing system. Employees were exposed to combustible hazards during manual electrostatic powder spraying operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 L02 I
- Issued
- Nov 13, 2013
- Abate by
- Dec 20, 2013
- Penalty
- Initial $0 · Current $0
2440T405
General-duty citation text
29 CFR 1910.107(l)(2)(i): All non-deposited air-suspended powder was not safely removed via exhaust ducts to the powder recovery cyclone or receptacle: a. On or about 6/19/2013, Shop, the spray booth did not confine air-suspended coating powder to the spray booth. Employees were exposed to combustible dust hazards during manual electrostatic powder spraying operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 I08
- Issued
- Nov 13, 2013
- Abate by
- Dec 20, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
2440T405
General-duty citation text
29 CFR 1910.107(i)(8): Electrical equipment for electrostatic hand spraying was not so interlocked with the ventilation of the spraying area that the equipment cannot be operated unless the ventilation fan(s) are in operation: a. On or about 6/18/2013, Shop, electrical equipment for the manual electrostatic spray gun was not interlocked with the spray booth ventilation. Employees were exposed to combustible dusts hazards during manual electrostatic powder spraying operations.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.132 A
- Issued
- Nov 13, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
2440T405
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a. On or about 6/18/2013, Shop, protective clothing was not used to prevent an employee's arms, legs, neck, feet, head, and street clothing from powder coating contamination during electrostatic hand spraying of powder coatings which exposes employees to skin absorption of hazardous substances.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.132 F01
- Issued
- Nov 13, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $0 · Current $0
2440T405
General-duty citation text
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: a. On or about 6/18/2013, Shop, personal protective equipment training was not provided to employees who conduct electrostatic hand spraying of powder coatings which exposes employees to hazardous substances.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.136 A
- Issued
- Nov 13, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.136(a): The employer did not ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet are exposed to electrical hazards: a. On or about 6/18/2013, Shop, the employer did not ensure use of conductive footwear appropriate for electrostatic hand spraying of powder coatings. Employees who operated electrostatic powder spray guns were potentially exposed to electric shock hazards during powder coat spraying
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.138 A
- Issued
- Nov 13, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $0 · Current $0
2440T405
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: a. On or about 6/18/2013, Shop, hand protection was not required to be worn during electrostatic hand spraying of powder coatings which exposes employees to skin absorption of harmful substances.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Nov 13, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $1,600 · Current $650 Reduced
2440T405
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. On or about 6/18/2013, Shop, a written respiratory protection program with work-site specific procedures was not developed and implemented for employees required to wear respirators for electrostatic hand spraying of powder coatings which exposes employees to airborne hazardous substances
Recent events (2)
- — I (S) $650
- — Z (S) $1600
1910.134 G01 I A
- Issued
- Nov 13, 2013
- Abate by
- Nov 15, 2013
- Penalty
- Initial $0 · Current $0
2440T405
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a. On or about 6/18/2013, Shop, An employee had facial hair that interfered with the seal of a full face elastomeric respirator worn during electrostatic hand spraying of powder coatings which exposes the employee to airborne hazardous substances.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Broken Arrow Powder Coating, INC.
View Broken Arrow Powder Coating, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339126229.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.