OSHA Inspection: D.R. NICKELSON AND COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of D.R. NICKELSON AND COMPANY, INC. in 229 NW WILKS LANE, LAKE CITY, FL 32055 (NAICS 321918). OSHA activity number 339128811.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D.R. Nickelson and Company, INC. for free Get an email when a new federal OSHA severe-injury report for D.R. Nickelson and Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
229 NW WILKS LANE
City
LAKE CITY
State
FL
ZIP
32055
Mailing
P.O. BOX 1744, LAKE CITY, FL 32056
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
15
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2013
Abate by
Oct 3, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A-D of this section:  a.  On or about June 20, 2013, at the manufacturing shop, the employer did not have clear and specific written energy control procedures for machinery, such as but not limited to the Biesse AKRON 440-X and the Biesse Rover A3.40, exposing employees to caught-in and amputation hazards.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2013
Abate by
Oct 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a.  On or about June 20, 2013, at the manufacturing shop, the employer did conduct a periodic inspection of the energy control procedure for the Biesse AKRON 440-X and the Biesse Rover A3.40, among other machinery with potential to store energy, exposing employees to caught-in and amputation hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2013
Abate by
Oct 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:   a.  On or about June 20, 2013, at the manufacturing shop, operators and maintenance employee of the Biesse AKRON 440A-X and Biesse Rover A3.40 had not been trained by the employer to recognize hazardous energy sources nor the methods for controlling and isolationg that energy, exposing them to caught-in and amputation hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 16, 2013
Abate by
Sep 12, 2013
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a.  On or about June 20, 2013, at the manufacturing shop, the air pressure of the pneumatic air gun used by employees to clean up the Biesse AKRON 440A-X edge banding machine measured 45 p.s.i..
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

View D.R. Nickelson and Company, INC.'s full OSHA safety record →