On , OSHA opened a referral safety inspection of CONCRETE WALLS, INC in NEXT TO 208 SAMMONS POND, MIDDLETOWN, DE 19709 (NAICS 238110). OSHA activity number 339129256.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONCRETE WALLS, INC
- Site address
- NEXT TO 208 SAMMONS POND
- City
- MIDDLETOWN
- State
- DE
- ZIP
- 19709
- Mailing
- P O BOX 4434, WILMINGTON, DE 19809
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 K01
- Issued
- Aug 21, 2013
- Abate by
- Sep 10, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems a) Jobsite- Next to 208 Sammons Pond St. Middletown, DE - Employees were exposed to cave-in hazards while inside a 6 foot deep excavation with type B soil where 90 degree walls were sloughing and the excavation had not been inspected by a competent person. Observed on or about 6/21/13. NOTE: Pursuant to 29 CFR 1903.19, the employer must submit abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1926.21 B02
- Issued
- Aug 21, 2013
- Abate by
- Sep 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury a) Jobsite- Next to 208 Sammons Pond St. Middletown, DE - Employees were exposed to cave-in hazards while inside an excavation, without training to recognize, avoid and prevent unsafe working conditions. Observed on or about 6/21/13. NOTE: Pursuant to 29 CFR 1903.19, the employer must submit abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.651 J02
- Issued
- Aug 21, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) Jobsite-Next to 208 Sammons Pond St. Middletown, DE - Employees were exposed to cave-in hazards while inside a 6 foot deep excavation approximately 60 feet long by 40 wide with type B soil and 90 degree walls, where excavated material was place up to the edge of the excavation. Observed on or about 6/21/13. NOTE: Pursuant to 29 CFR 1903.19, the employer must submit abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement
Recent events (2)
- — I (S) $0
- — Z (S) $1600
More inspections at Concrete Walls, INC
View Concrete Walls, INC's full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339129256.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.