ORRVILLE, OH ·
OSHA Inspection: JLG INDUSTRIES INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JLG INDUSTRIES INC. in 600 EAST CHESTNUT ST., ORRVILLE, OH 44667 (NAICS 333120). OSHA activity number 339131906.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JLG INDUSTRIES INC.
- Site address
- 600 EAST CHESTNUT ST.
- City
- ORRVILLE
- State
- OH
- ZIP
- 44667
- Mailing
- 600 EAST CHESTNUT ST., ORRVILLE, OH 44667
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333120
- Employees
- 700
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.254 D09 III
- Issued
- Sep 9, 2013
- Penalty
- Initial $7,000 · Current $3,675 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced. On or about June 11, 2013, during welding operations, the employer did not ensure that cables with damaged insulation were taken out of service and replaced.
Recent events (2)
- · I (S) $3675
- · Z (S) $7000
1910.254 A03
- Issued
- Sep 9, 2013
- Abate by
- Oct 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.254(a)(3): Workmen designated to operate arc welding equipment had not been properly instructed and qualified to operate such equipment as specified in 29 CFR 1910.254(d). On or about June 11, 2013, during welding operations, the employer did not ensure employees designated to operate arc welding equipment had been properly trained to operate such equipment in accordance with CFR 1910.254(d)
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at JLG Industries INC.
View JLG Industries INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333120)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339131906.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.