Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VULCAN FINNED TUBES L.P.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VULCAN FINNED TUBES L.P. in 27951 COMMERCIAL PARK DR, TOMBALL, TX 77375 (NAICS 332410). OSHA activity number 339148868.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vulcan Finned Tubes L.P. — free Get an email when a new federal OSHA severe-injury report for Vulcan Finned Tubes L.P. is published. One employer, no account, unsubscribe in one click.
Site address
27951 COMMERCIAL PARK DR
City
TOMBALL
State
TX
ZIP
77375
Mailing
27951 COMMERCIAL PARK DR, TOMBALL, TX 77375
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
22
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 4 exposed
Issued
Jul 17, 2013
Abate by
Jul 23, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
OSH ACT of 1970 Section (5) (a) (1): Section 5(a) (1) of the Occupational Safety and Health Act of 1970:  The employer does not furnish to each of his employees employment and a place of employment which are free from the recognized hazards of being struck-by, which are causing or likely to cause death or serious physical harm to employees.   a. This violation was observed on or about June 26, 2013, in the center section of the fabrication area of the facility where employees were exposed to struck-by hazards when lifting material using a Proserv 5-ton gantry cranes without a functioning safety latch on the hoisting hook.    b. This violation was observed on or about June 26, 2013, in the back section of the fabrication area of the facility where employees were exposed to struck-by hazards when lifting material using a Proserv 5-ton gantry cranes without a functioning safety latch on the hoisting hook.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation describing the actions it is taking to ensure that employees are not exposed to struck-by hazards.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 17, 2013
Abate by
Jul 23, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  The employer does not guard all the rotating parts of machines whose operation exposes employees to injury.  This violation was observed on or about June 26, 2013, in the fabrication area where employees were exposed to caught-in and caught-by hazards when operating #4 L-Foot machine without guarding on the rotating parts.     Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all machines that have exposed rotating parts are guarded.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.219 F01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 17, 2013
Abate by
Jul 23, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii).  This violation was observed on or about June 26, 2013, in the fabrication are of the facility where employees were exposed to caught-in hazards when operating "Serrator #4" with gears exposed without any type of guarding.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all exposed gears are properly guarded.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View Vulcan Finned Tubes L.P.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339148868.