FAIRVIEW, PA —
OSHA Inspection: ADVANCED FINISHING USA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADVANCED FINISHING USA, INC. in 7401 KLIER DRIVE, FAIRVIEW, PA 16415 (NAICS 332812). OSHA activity number 339149460.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED FINISHING USA, INC.
- Site address
- 7401 KLIER DRIVE
- City
- FAIRVIEW
- State
- PA
- ZIP
- 16415
- Mailing
- 7401 KLIER DRIVE, FAIRVIEW, PA 16415
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 40
- Ownership type
- A
Citations
19 citations on file for this inspection.
1910.23 C01
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, Pangborn LK Table Blast Cleaning System, on or about June 27, 2013 and times prior thereto: An employee accessing / working on the top of the Pangborn LK Table Blast Cleaning System to clean a screen was exposed to a fall hazard of 7.9 feet. This employee was not protected by any guardrail systems and/or other fall protection devices. IN THE ALTERNATIVE: 29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, Pangborn LK Table Blast Cleaning System, on or about June 27, 2013 and times prior thereto: An employee accessing / working on the top of the Pangborn LK Table Blast Cleaning System to clean a screen was exposed to a fall hazard of 7.9 feet. This employee was not protected by a personal fall arrest system (PFAS) and/or other fall protection devices.
Recent events (2)
- — I (S) $2800
- — Z (S) $2800
1910.23 E01
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wash line / waste water pit, on or about November 7, 2013 and times prior thereto: The top-rail for the waste water pit's chain guardrail system was too low. The top of the chain was 33 inches from the ground. B.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wash line / waste water pit, on or about November 7, 2013 and times prior thereto: The chain guardrail system for the waste water pit was not equipped with a mid-rail/intermediate rail.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.24 H
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, Pangborn LK Table Blast Cleaning System, on or about November 7, 2013 and times prior thereto: An employee utilizes fixed industrial stairs to access the top of the Pangborn LK Table Blast Cleaning System. The exposed sides and top section of the stairs were not equipped with standard hand and guard railings.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B05 IV
- Issued
- Dec 10, 2013
- Abate by
- Feb 14, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, west side of the wet spray painting area, on or about November 7, 2013 and times prior thereto: Employees perform spray painting operations at the face of a GFS spray paint booth. The spray booth is not equipped with automatic sprinklers. B.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, east side of the wet spray painting area, on or about November 7, 2013 and times prior thereto: Employees perform spray painting operations at the face of a GFS spray paint booth. The spray booth is not equipped with automatic sprinklers.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.107 B09
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, west side of the wet spray painting area, on or about November 7, 2013 and times prior thereto: Employees perform spray painting operations at the face of a GFS spray paint booth. Painting products, supplies and waste were stored within one foot of the spray booth. B.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, east side of the wet spray painting area, on or about November 7, 2013 and times prior thereto: Employees perform spray painting operations at the face of a GFS spray paint booth. Painting products and waste were stored within one foot of the spray booth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 D04 V
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(v): Dispensing was not by approved pump or self-closing faucet: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wet spray painting area, on or about November 7, 2013 and times prior thereto: Employees were dispensing Railplex 2.0 Grey Primer from a drum into a metal can. The liquid was dispensed from the drum through a quarter turn valve and small pipes.
Recent events (2)
- — I (S) $1000
- — Z (S) $2800
1910.107 E09
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(9): Flammable liquids for use in spraying operations were transferred from one container to another without both containers being effectively bonded and grounded to prevent discharge sparks of static electricity. A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wet spray painting area, on or about November 7, 2013 and times prior thereto: Employees were dispensing Railplex 2.0 Grey Primer from a drum into a metal can. The drum was not grounded during the transfer process. A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wet spray painting area, on or about November 7, 2013 and times prior thereto: Employees were dispensing Railplex 2.0 Grey Primer from a drum into a metal can. The drum was not bonded to the metal can during the transfer process.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wet spray painting area, on or about November 7, 2013 and times prior thereto: A General Electric motor, two pulley systems, and two rolls were used to rotate a drum of primer for a mixing process. The pulleys, which are located less than one foot from the floor, were not guarded.
Recent events (2)
- — I (S) $1000
- — Z (S) $2800
1910.212 A04
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(4): Revolving drum(s), barrel(s), or container(s) were not guarded by enclosure(s) which were interlocked with the drive mechanism so that the barrel(s), drum(s), or container(s) could not revolve unless the enclosure(s) were in place: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wet spray painting area, on or about November 7, 2013 and times prior thereto: A General Electric motor, two pulley systems, and two rolls were used to rotate a drum of primer for a mixing process. The rotating rollers and drum were not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $4,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wet spray painting area, on or about November 7, 2013 and times prior thereto: The flexible cord for the paint mixer had damage at the cord cap and at the General Electric motor junction box.
Recent events (2)
- — I (S) $1000
- — Z (S) $4200
1910.305 B02 I
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wet spray painting area, on or about November 7, 2013 and times prior thereto: A General Electric motor was used to power a paint mixer. The junction box on the General Electric motor was not equipped with a cover plate.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, electrical panel #3, on or about June 27, 2013 and times prior thereto: A plasma cutter was stored in front of panel #3.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E02
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $2,100 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wet spray painting area, on or about November 7, 2013 and times prior thereto: An Amerex multi-purpose dry chemical fire extinguisher was not inspected on a monthly basis. B.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, south production area, on or about June 27, 2013 and times prior thereto: An Amerex multi-purpose dry chemical fire extinguisher was not inspected on a monthly basis.
Recent events (2)
- — I (S) $1000
- — Z (S) $2100
1910.157 G02
- Issued
- Dec 10, 2013
- Abate by
- Jan 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, on or about November 7, 2013 and times prior thereto: Employees did not receive initial fire extinguisher training. B.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, on or about November 7, 2013 and times prior thereto: Employees did not receive annual fire extinguisher training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, maintenance area, on or about November 7, 2013 and times prior thereto: A Jet 6 inch bench top grinder (M/N: JBG-6A, S/N: 8046967) was not equipped with an adjustable tongue guard.
Recent events (2)
- — I (S) $2800
- — Z (S) $2800
1910.215 A04
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, maintenance area, on or about November 7, 2013 and times prior thereto: A Jet 6 inch bench top grinder (M/N: JBG-6A, S/N: 8046967) was not equipped with an adjustable work rest.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D01 I
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, production area, on or about June 27, 2013 and times prior thereto: Employees were working with and around parts made for Lord Corporation which were hung from hooks during the spray coating and heat treating process. The company provided toe caps for employee use, however the use of toe caps / safety shoes were not enforced.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 D02
- Issued
- Dec 10, 2013
- Abate by
- Jan 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, on or about June 27, 2013 and times prior thereto: The company did not document and certify the PPE hazard assessment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.176 B
- Issued
- Dec 10, 2013
- Abate by
- Jan 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: A.) Advanced Finishing USA, Inc., 7401 Klier Drive, Fairview, PA 16415, wash line, on or about June 27, 2013 and times prior thereto: A chemical tote of Parco Cleaner 800 was sitting on a spill containment pallet at an angle.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Advanced Finishing USA, INC.
View Advanced Finishing USA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339149460.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.