Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: SANITARY LINEN SUPPLY INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SANITARY LINEN SUPPLY INC in 1100 SIXTH AVE, NEPTUNE, NJ 07753 (NAICS 812331). OSHA activity number 339151193.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sanitary Linen Supply INC for free Get an email when a new federal OSHA severe-injury report for Sanitary Linen Supply INC is published. One employer, no account, unsubscribe in one click.
Site address
1100 SIXTH AVE
City
NEPTUNE
State
NJ
ZIP
07753
Mailing
1100 SIXTH AVE, NEPTUNE, NJ 07753
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812331
Employees
85
Ownership type
Private (A)

10 citations on file for this inspection.

1910.23 D01 IV

Serious Gravity 1 1 instance 85 exposed
Issued
Dec 13, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.23(d)(1)(iv): The employer did not ensure that stairs with four or more risers that were more than 44 inches wide but less than 88 inches wide had a stair railing on each open side:   a) Outside behind maintenance shop: Stairs that were part of the emergency exit route did not have standard railings on each side consisting of top and intermediate rails and posts , on or about 6/26/13.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $2100

1910.133 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Dec 13, 2013
Abate by
Jan 10, 2014
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a) Maintenance area/boiler room: The employer did not ensure that employees wore goggles when handling WI-243 boiler treatment, a corrosive chemical, on or about 6/26/13.   b) North side of  make-up area: The employer did not provide and ensure that employees wore goggles when using Rust Go, a corrosive chemical, on or about 6/26/13.
Recent events (2)
  • · I (S) $2625
  • · Z (S) $3500

1910.151 C

Serious Gravity 5 2 instances 4 exposed
Issued
Dec 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   a) Maintenance area/boiler room: An eyewash station capable of 15 minutes of continuous flush was not available where employees used WI-243 boiler treatment, a corrosive chemical, on or about 6/26/13.   b) North side of make-up area: An eyewash station capable of 15 minutes of continuous flush was not available where employees used Rust Go, a corrosive chemical, on or about 6/26/13.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 40 exposed
Issued
Dec 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   a) Throughout facility:  The employer did not develop and implement a written hazard communication program for chemicals used by employees, such as, but not limited to, CQ-209, Oxygen, propane, acetylene,, Peracid Plus Concentrated Peraceitc acid bleach and CC Sour and corrosive chemicals, such as, but not limited to, Chlo-rid Rust Go, WI-243 boiler treatment, Sodium Hypochlorite and Sulfuric acid, on or about 6/26/13.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 40 exposed
Issued
Dec 13, 2013
Abate by
Jan 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   a) Throughout facility:  The employer did not provide training to employees on the chemicals used in the facility, such as, but not limited to, CQ-209, Oxygen, propane, acetylene,, Peracid Plus Concentrated Peraceitc acid bleach and CC Sour and corrosive chemicals, such as, but not limited to, Chlo-rid Rust Go, WI-243 boiler treatment, sodium hypochlorite and Sulfuric acid, on or about 6/26/13.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 13, 2013
Abate by
Jan 10, 2014
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:   a) Outside behind maintenance room: Oxygen cylinders were stored next to and with cylinders of acetylene and propane, on or about 6/26/13.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $2100

1910.303 B02

Serious Gravity 1 5 instances 50 exposed
Issued
Dec 13, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Laundry area next to an apron folding machines: A cord was hardwired to an overhead light and used to power a strapping machine, on or about 6/26/13.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $2100

1910.303 G01 II

Serious Gravity 1 2 instances 20 exposed
Issued
Dec 13, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   a) Laundry area across from apron folding machines: An electrical panel operating the building's main power supply was blocked by a bench, on or about 6/26/13.   b) East side of  make-up area: Electrical panels operating the waste water pump, roof fan and machinery were blocked by bins of linens and racks holding uniforms, on or about 6/26/13.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $2100

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 13, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   a) North side of make-up area:  Plugs on two Juki sewing machines had torn strain reliefs, on or about 6/26/13.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $2100

1910.305 G01 IV A

Serious Gravity 1 4 instances 50 exposed
Issued
Dec 13, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Laundry area across from apron folding machines: A power strip was used to power a microwave and a refrigerator, on or about 6/26/13.   b) Laundry area across from apron folding machines: A water fountain was powered by an extension cord, on or about 6/26/13.  c) Waste water pre-treatment set up area across from the maintenance shop/boiler room: A multiplug socket was used to power two pumps, on or about 6/26/13.  d) Outside wall of maintenance shop/boiler room: An extension cord was used to power a water fountain, on or about 6/26/13.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $2100

View Sanitary Linen Supply INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339151193.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.