COLLEGE STATION, TX ·
OSHA Inspection: RAMCO ERECTORS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RAMCO ERECTORS, INC. in FM 2818 F & B ROAD, COLLEGE STATION, TX 77845 (NAICS 238120). OSHA activity number 339152050.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAMCO ERECTORS, INC.
- Site address
- FM 2818 F & B ROAD
- City
- COLLEGE STATION
- State
- TX
- ZIP
- 77845
- Mailing
- 2218 PECH ROAD, HOUSTON, TX 77055
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 19
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 18, 2013
- Abate by
- Mar 1, 2014
- Penalty
- Initial $6,300 · Current $3,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being struck by falling materials. On or about June 22, 2013 malleable cast iron clips were used in the following locations to make eye splices in wire rope: a. Temporary support cables attached to rafters with connections made with malleable cast iron U-bolt type cable clamps.
Recent events (2)
- · I (S) $3000
- · Z (S) $6300
1926.21 B02
- Issued
- Dec 18, 2013
- Abate by
- Mar 1, 2014
- Penalty
- Initial $6,300 · Current $4,500 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: On or about June 22, 2013 workers were exposed to fall from elevation and struck by structural steel hazards while erecting building 6. The employer failed to train workers in the following hazards: a. Cross-bracing rods used in the braced bay were not all put in place. Cross bracing is essential to the building process and makes for a stable structure. b. All connections were not tightened. After the bay is erected and aligned, it is necessary to tighten all purlin, grid and flange brace connections.
Recent events (2)
- · I (S) $4500
- · Z (S) $6300
1926.251 A01
- Issued
- Dec 18, 2013
- Abate by
- Mar 1, 2014
- Penalty
- Initial $4,500 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.251(a)(1): Rigging equipment for material handling was not inspected prior to use on each shift and as necessary during its use to ensure that it was safe and defective rigging equipment was not removed from service: On or about June 22, 2013 a 5/8 inch diameter wire rope sling, serial number 145270-23, 3.9 ton capacity had a hook safety latch that did not close. The sling was used to lift rafters, exposing employees to the hazards of being struck by falling materials. In the alternative: 29 CFR 1926.753(c)(5): Safety latches on hooks were deactivated or made inoperable:
Recent events (2)
- · I (O) $1000
- · Z (S) $4500
1926.251 C05 I
- Issued
- Dec 18, 2013
- Abate by
- Mar 1, 2014
- Penalty
- Initial $6,300 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.251(c)(5)(i): The U section of U-bolt wire rope clip(s) used to form eyes was not in contact with the dead end of the rope: On or about June 22, 2013 Wire rope clips were put on backwards in the following locations found at the Building 6 construction site exposing workers to the hazards of being struck by materials: b: On sling used as temporary support for steel structure being erected.
Recent events (2)
- · I (S) $3000
- · Z (S) $6300
1926.752 E
- Issued
- Dec 18, 2013
- Abate by
- Mar 1, 2014
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1926.752(e): Site-specific erection plan. Where employers elect, due to conditions specific to the site, to develop alternate means and methods that provide employee protection in accordance with �� 1926.753(c)(5), �� 1926.757(a)(4) or �� 1926.757(e)(4), a site-specific erection plan was not developed by a qualified person and was not available at the work site. Guidelines for establishing a site-specific erection plan are contained in Appendix A to this subpart. At the site, on or about June 22, 2013, and in times priorto and thereafter, a specific erection plan for the methods and sequences used was not provided, exposing employees to the hazards of being struck by structural steel. The buildings were erected from one end to the other end and not following the bay erection sequence recommended by the manufacturer. a. Building 1. b. Building 2. c. Building 3. d. Building 6. e. Building 7.
Recent events (2)
- · I (S) $6300
- · Z (S) $6300
1926.754 A
- Issued
- Dec 18, 2013
- Abate by
- Mar 1, 2014
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1926.754(a): Structural stability was not maintained at all times during the erection process. On or about June 22, 2013, Missing or not connected critical structural members, cross bracing rods and flange braces were not replaced with temporary rigging of equivalent strength in the following buildings, resulting in the collspse of Building 6, exposing employees to the hazards of being struck by steel and falling from elevations: a. Building 3 b. Building 6 c. Building 8
Recent events (2)
- · I (S) $0
- · Z (S) $6300
1926.760 D01
- Issued
- Dec 18, 2013
- Abate by
- Mar 1, 2014
- Penalty
- Initial $4,500 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.760(d)(1): Guardrail systems, safety net systems, personal fall arrest systems, positioning device systems and their components did not conform to the criteria in �� 1926.502 (see Appendix G to this subpart). a) On or about June 22, 2013, snap hook, EN 362 2004/T Patented 0120 CE, had a defective safety interlock. The hook was located on a safety harness worn by iron workers bolting purlins on top of a rafter over 24 feet of elevation in Building 6, exposing employees to the hazards of falls. b) On or about June 22, 2013, and in times prior thererto, wire rope clips used for rigging the lifelines were not of the drop-forged type but were malleable cast iron, subject to breakage under load, exposing employees to the hazards of falls.
Recent events (2)
- · I (S) $3000
- · Z (S) $4500
More inspections at Ramco Erectors, INC.
View Ramco Erectors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339152050.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.