Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: RAMCO ERECTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RAMCO ERECTORS, INC. in FM 2818 F & B ROAD, COLLEGE STATION, TX 77845 (NAICS 238120). OSHA activity number 339152050.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ramco Erectors, INC. for free Get an email when a new federal OSHA severe-injury report for Ramco Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
FM 2818 F & B ROAD
City
COLLEGE STATION
State
TX
ZIP
77845
Mailing
2218 PECH ROAD, HOUSTON, TX 77055
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
19
Ownership type
Private (A)

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 19 exposed
Issued
Dec 18, 2013
Abate by
Mar 1, 2014
Penalty
Initial $6,300 · Current $3,000 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being struck by falling materials.    On or about June 22, 2013 malleable cast iron clips were used in the following locations to make eye splices in wire rope:    a.  Temporary support cables attached to rafters with connections made with malleable cast iron U-bolt type cable clamps.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $6300

1926.21 B02

Serious Gravity 10 3 instances 19 exposed
Issued
Dec 18, 2013
Abate by
Mar 1, 2014
Penalty
Initial $6,300 · Current $4,500 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury:    On or about June 22, 2013 workers were exposed to fall from elevation and struck by structural steel hazards while erecting building 6. The employer failed to train workers in the following hazards:      a. Cross-bracing rods used in the braced bay were not all put in place.  Cross bracing is essential to the building process and makes for a stable structure.  b. All connections were not tightened.  After the bay is erected and aligned, it is necessary to tighten all purlin, grid and flange brace connections.
Recent events (2)
  • · I (S) $4500
  • · Z (S) $6300

1926.251 A01

Other-than-serious 1 instance 19 exposed
Issued
Dec 18, 2013
Abate by
Mar 1, 2014
Penalty
Initial $4,500 · Current $1,000 Reduced
29 CFR 1926.251(a)(1): Rigging equipment for material handling was not inspected prior to use on each shift and as necessary during its use to ensure that it was safe and defective rigging equipment was not removed from service:    On or about June 22, 2013 a 5/8 inch diameter wire rope sling, serial number 145270-23, 3.9 ton capacity had a hook safety latch that did not close.  The sling was used to lift rafters, exposing employees to the hazards of being struck by falling materials.    In the alternative: 29 CFR 1926.753(c)(5): Safety latches on hooks were deactivated or made inoperable:
Recent events (2)
  • · I (O) $1000
  • · Z (S) $4500

1926.251 C05 I

Serious Gravity 10 2 instances 19 exposed
Issued
Dec 18, 2013
Abate by
Mar 1, 2014
Penalty
Initial $6,300 · Current $3,000 Reduced
29 CFR 1926.251(c)(5)(i): The U section of U-bolt wire rope clip(s) used to form eyes was not in contact with the dead end of the rope:    On or about June 22, 2013 Wire rope clips were put on backwards in the following locations found at the Building 6 construction site exposing workers to the hazards of being struck by materials:    b:  On sling used as temporary support for steel structure being erected.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $6300

1926.752 E

Serious Gravity 10 6 instances 19 exposed
Issued
Dec 18, 2013
Abate by
Mar 1, 2014
Penalty
Initial $6,300 · Current $6,300
29 CFR 1926.752(e): Site-specific erection plan. Where employers elect, due to conditions specific to the site, to develop alternate means and methods that provide employee protection in accordance with �� 1926.753(c)(5), �� 1926.757(a)(4) or �� 1926.757(e)(4), a site-specific erection plan was not developed by a qualified person and was not available at the work site. Guidelines for establishing a site-specific erection plan are contained in Appendix A to this subpart.    At the site, on or about June 22, 2013, and in times priorto and thereafter, a specific erection plan for the methods and sequences used was not provided, exposing employees to the hazards of being struck by structural steel.  The buildings were erected from one end to the other end and not following the bay erection sequence recommended by the manufacturer.     a.  Building 1.  b.  Building 2.   c.  Building 3.  d.  Building 6.  e.  Building 7.
Recent events (2)
  • · I (S) $6300
  • · Z (S) $6300

1926.754 A

Serious Gravity 10 3 instances 19 exposed
Issued
Dec 18, 2013
Abate by
Mar 1, 2014
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1926.754(a): Structural stability was not maintained at all times during the erection process.    On or about June 22, 2013, Missing or not connected critical structural members, cross bracing rods and flange braces were not replaced with temporary rigging of equivalent strength in the following buildings, resulting in the collspse of Building 6, exposing employees to the hazards of being struck by steel and falling from elevations:    a.  Building 3  b.  Building 6  c.  Building 8
Recent events (2)
  • · I (S) $0
  • · Z (S) $6300

1926.760 D01

Serious Gravity 5 2 instances 4 exposed
Issued
Dec 18, 2013
Abate by
Mar 1, 2014
Penalty
Initial $4,500 · Current $3,000 Reduced
29 CFR 1926.760(d)(1): Guardrail systems, safety net systems, personal fall arrest systems, positioning device systems and their components did not conform to the criteria in �� 1926.502 (see Appendix G to this subpart).    a) On or about June 22, 2013, snap hook, EN 362 2004/T Patented 0120 CE, had a defective safety interlock.  The hook was located on a safety harness worn by iron workers bolting purlins on top of a rafter over 24 feet of elevation in Building 6, exposing employees to the hazards of falls.    b) On or about June 22, 2013, and in times prior thererto, wire rope clips used for rigging the lifelines were not of the drop-forged type but were malleable cast iron, subject to breakage under load, exposing employees to the hazards of falls.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $4500

View Ramco Erectors, INC.'s full OSHA safety record →