Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CROSSROADS COOPERATIVE ASSOCIATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CROSSROADS COOPERATIVE ASSOCIATION in 502 LINCOLN, GURLEY, NE 69141 (NAICS 424510). OSHA activity number 339153025.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crossroads Cooperative Association — free Get an email when a new federal OSHA severe-injury report for Crossroads Cooperative Association is published. One employer, no account, unsubscribe in one click.
Site address
502 LINCOLN
City
GURLEY
State
NE
ZIP
69141
Mailing
P.O. BOX 153, GURLEY, NE 69141
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 27, 2013
Penalty
Initial $2,225 · Current $1,558 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  The employer failed to protect employees from potential emergency evacuation hazards associated with unmarked emergency exits.  This was most recently evident during the inspection of the maintenance area of the facility located at 501 Lincoln Street, Gurley, NE 69141, where the employer has and exit door identified under the emergency exit plan as a primary exit route but is not marked with a visible "Exit"sign.
Recent events (2)
  • — I (S) $1557.5
  • — Z (S) $2225

1910.110 F02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2013
Penalty
Initial $2,618 · Current $1,833 Reduced
29 CFR 1910.110(f)(2)(i): Containers in storage were not located in an area that minimized exposure to excessive temperature rise, physical damage, or tampering from unauthorized persons:  The employer is failing to protect employees from potential explosive hazards associated with improperly storing LP containers.  This was most recently evident during the inspection of the storage area of the facility located at 501 Lincoln Street, Gurley, NE 69141, where the employer is storing a LP gas container in the open, unsecured and exposed to tampering or possible contact from moving forklifts or personnel.
Recent events (2)
  • — I (S) $1832.6
  • — Z (S) $2618

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2013
Penalty
Initial $2,618 · Current $1,833 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:               The employer failed to protect employees from potential explosion hazards associate with improper storage of oxygen tanks.  This was most recently evident during the inspection of the maintenance area of the facility located at 501 Lincoln Street, Gurley, NE 69141, where the employer is storing oxygen and acetylene gas cylinders within 20 feet of each other exposing employees to increase potential explosion hazards in the event of a fire.
Recent events (2)
  • — I (S) $1832.6
  • — Z (S) $2618

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2013
Abate by
Oct 17, 2013
Penalty
Initial $3,273 · Current $2,291 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  The employer failed to protect employees from potential electrical hazards associate with improper use and wiring of an air compressor directly into an electrical panel box.  This was most recently evident during the inspection of the maintenance area of the facility located at 501 Lincoln Street, Gurley, NE 69141, where the employer has employees using the air compressor that has a wiring configuration utilizing the circuit breaker box as means of overvoltage protection by running standard insulated wiring back into an outlet and not running the approved wiring though conduit as intended by the manufacturer.
Recent events (2)
  • — I (S) $2291.1
  • — Z (S) $3273

View Crossroads Cooperative Association's full OSHA safety record →