OSHA Inspection: U.S. COAST GUARD INDUSTRIAL PRODUCT DETACHMENT (IPD)

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. COAST GUARD INDUSTRIAL PRODUCT DETACHMENT (IPD) in 1001 S. SEASIDE AVE BLDG. 14, SAN PEDRO, CA 90731 (NAICS 332710). OSHA activity number 339157224.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Coast Guard Industrial Product Detachment (IPD) for free Get an email when a new federal OSHA severe-injury report for U.S. Coast Guard Industrial Product Detachment (IPD) is published. One employer, no account, unsubscribe in one click.
Site address
1001 S. SEASIDE AVE BLDG. 14
City
SAN PEDRO
State
CA
ZIP
90731
Mailing
1001 S. SEASIDE AVE BLDG. 14, SAN PEDRO, CA 90731
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
8
Ownership type
Federal government (D)

17 citations on file for this inspection.

1910.176 C

Serious Gravity 5 3 instances 5 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage:  a) Machine shop, near plate roller  - On or about 6/27/2013, metal pieces were stored unsecured from sliding or falling and posed tripping hazards.  b) Machine shop, small bolt storage area - On or about 6/27/2013, air hoses were stored on the floor and posed tripping hazards.  c) Rigging shop, at bottom of stairs - On or about 6/27/2013, an air hose on the floor posed tripping hazards.
Recent events (1)
  • · Z (S) $0

1910.178 L01 II

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(ii): 29 CFR 1910.178(l)(1)(ii):  The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck:  At the establishment - On or about 6/27/2013, the employer did not ensure that each non-IPD operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting such employees to operate the establishment's power industrial trucks.
Recent events (1)
  • · Z (S) $0

1910.178 L04 I

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(i): Refresher training in relevant topics was not provided to the operator who had been involved in an accident or near-miss incident:  At the establishment - On or about 6/27/2013, the employer did not enforce refresher training and reevaluation requirements for forklift operator(s) who were involved with near misses causing damage to the forklifts.
Recent events (1)
  • · Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Powered industrial trucks were not examined before being placed in service. Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift:   At the establishment - On or about 6/27/2013, and prior thereto, powered industrial trucks used jointly by the establishment and other Coast Guard units on a round-the-clock basis were not examined for defects before being placed in service and after each shift.
Recent events (1)
  • · Z (S) $0

1910.184 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material:   Rigging shop, Rigging #30 - On or about 6/27/2013, and times prior thereto, the label was not legible and did not show the rated capacity for each type of hitch.
Recent events (1)
  • · Z (S) $0

1910.184 I09 III

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service:   a) Rigging shop, Rigging #42 - On or about 6/27/2013, and prior thereto, a synthetic web sling with snags was not immediately removed from service.  b) Rigging shop, Rigging #5 - On or about 6/27/2013, and prior thereto, a synthetic web sling with snags was not immediately removed from service.
Recent events (1)
  • · Z (S) $0

1910.184 F05 III

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.184(f)(5)(iii): Wire rope sling(s) that had kinking, crushing, bird caging or other damage resulting in distortion of the wire rope structure were not immediately removed from service:   Rigging shop - On or about 6/27/2013, and times prior thereto, wire rope with kinking damage were not immediately removed from service.
Recent events (1)
  • · Z (S) $0

1910.212 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(2): Machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves:  Machine shop, plate roller - On or about 6/27/2013, and at times prior thereto, forward and reverse foot controls were not labeled. In addition, the foot control strain relief exhibited damage.
Recent events (1)
  • · Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   Welding storage area, grinder adjacent to bay door - On or about 6/27/2013, the distance between the left wheel and the end of the safety guard was greater than one fourth inch.
Recent events (1)
  • · Z (S) $0

1910.303 G01 II

Serious Gravity 5 2 instances 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) Panel # 4 -  On or about 6/27/2013, a welding cart was stored in front of the electrical panel.  b) Panel # 6 -  On or about 6/27/2013, an umbrella and bucket were stored in front of the electrical panel.
Recent events (1)
  • · Z (S) $0

1910.304 B03 II C 3

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(3)(ii)(C)(3): 29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug found damaged or defective was used before being repaired:  a) Machine shop, electric cart charging area - On or about 6/27/2013, an extension cord used for charging an electric cart had damage to its insulation.  a) Machine shop, work bench - On or about 6/27/2013, an extension cord used to power overhead lights had damage to its insulation.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 2 instances 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Break room - On or about 6/27/2013, an extension cord was used as permanent wiring to supply power to a computer.  b) Machine shop - On or about 6/27/2013, an extension cord was used as permanent wiring to supply power to overhead lighting.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  Break room - On or about 6/27/2013, an extension cord was run through the ceiling and wall.
Recent events (1)
  • · Z (S) $0

1910.305 J02 IV

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:  Break room - On or about 6/27/2013, an electrical outlet had no GFCI protection.
Recent events (1)
  • · Z (S) $0

1917.42 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1917.42(a)(1): Loose gear, such as slings, chains, bridles, blocks, and hooks, were not inspected, and/or defects were not corrected prior to reuse:   At the establishment - On or about 6/27/2013, and times prior thereto, loose gear were not inspected for any defects and corrected before reuse after the completion of each use by multiple Coast Guard units.
Recent events (1)
  • · Z (S) $0

1917.42 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1917.42(a)(2): All loose gear, such as slings, chains, bridles, blocks, and hooks, was not inspected by the employer or their authorized representative before each use and during its use, to ensure that it was safe:  At the establishment - On or about 6/27/2013, and times prior thereto, loose gear were not inspected by the employer or their authorized representative before and during its use by other Coast Guard units to ensure that it was safe.
Recent events (1)
  • · Z (S) $0

1917.42 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2013
Abate by
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1917.42(g)(2)(iii): Synthetic web slings were not removed from service when they were damaged by snags, punctures, tears, or cuts:  Rigging shop - On or about 6/27/2013, and prior thereto, synthetic web sling with snags or tears were not immediately removed form service.
Recent events (1)
  • · Z (S) $0

View U.S. Coast Guard Industrial Product Detachment (IPD)'s full OSHA safety record →