SAN PEDRO, CA ·
OSHA Inspection: U.S. COAST GUARD INDUSTRIAL PRODUCT DETACHMENT (IPD)
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. COAST GUARD INDUSTRIAL PRODUCT DETACHMENT (IPD) in 1001 S. SEASIDE AVE BLDG. 14, SAN PEDRO, CA 90731 (NAICS 332710). OSHA activity number 339271876.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. COAST GUARD INDUSTRIAL PRODUCT DETACHMENT (IPD)
- Site address
- 1001 S. SEASIDE AVE BLDG. 14
- City
- SAN PEDRO
- State
- CA
- ZIP
- 90731
- Mailing
- 1001 S. SEASIDE AVE BLDG. 14, SAN PEDRO, CA 90731
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 8
- Ownership type
- Federal government (D)
Citations
4 citations on file for this inspection.
1910.102 A
- Issued
- Sep 3, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.102(a): Cylinders. The in-plant transfer, handling, storage, and use of acetylene in cylinders did not comply with the provisions of CGA Pamphlet G-1-2003 ("Acetylene") (Compressed Gas Association, Inc., 11th ed., 2003): Outdoor, Acetylene storage rack - On or about 6/27/2013, acetylene cylinders were not strapped or chained securely to prevent them from falling.
Recent events (1)
- · Z (S) $0
1910.253 B04 III
- Issued
- Sep 3, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: Outdoor, Acetylene cage - On or about 6/27/2013, an oxygen cylinder was stored in the acetylene storage area.
Recent events (1)
- · Z (S) $0
1910.1200 F05 I
- Issued
- Sep 3, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: Machine shop - On or about 6/27/2013, a catch bucket for Kool Mist was not labeled with its chemical contents.
Recent events (1)
- · Z (S) $0
1910.1200 G01
- Issued
- Sep 3, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: Machine shop - On or about 6/27/2013, the employer did not have a material safety data sheet for Kool Mist.
Recent events (1)
- · Z (S) $0
More inspections at U.S. Coast Guard Industrial Product Detachment (IPD)
View U.S. Coast Guard Industrial Product Detachment (IPD)'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339271876.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.