Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: U.S. COAST GUARD INDUSTRIAL PRODUCT DETACHMENT (IPD)

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U.S. COAST GUARD INDUSTRIAL PRODUCT DETACHMENT (IPD) in 1001 S. SEASIDE AVE BLDG. 14, SAN PEDRO, CA 90731 (NAICS 332710). OSHA activity number 339271876.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Coast Guard Industrial Product Detachment (IPD) for free Get an email when a new federal OSHA severe-injury report for U.S. Coast Guard Industrial Product Detachment (IPD) is published. One employer, no account, unsubscribe in one click.
Site address
1001 S. SEASIDE AVE BLDG. 14
City
SAN PEDRO
State
CA
ZIP
90731
Mailing
1001 S. SEASIDE AVE BLDG. 14, SAN PEDRO, CA 90731
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
8
Ownership type
Federal government (D)

4 citations on file for this inspection.

1910.102 A

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.102(a): Cylinders. The in-plant transfer, handling, storage, and use of acetylene in cylinders did not comply with the provisions of CGA Pamphlet G-1-2003 ("Acetylene") (Compressed Gas Association, Inc., 11th ed., 2003):    Outdoor, Acetylene storage rack - On or about 6/27/2013, acetylene cylinders were not strapped or chained securely to prevent them from falling.
Recent events (1)
  • · Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  Outdoor, Acetylene cage - On or about 6/27/2013, an oxygen cylinder was stored in the acetylene storage area.
Recent events (1)
  • · Z (S) $0

1910.1200 F05 I

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  Machine shop  - On or about 6/27/2013, a catch bucket for Kool Mist was not labeled with its chemical contents.
Recent events (1)
  • · Z (S) $0

1910.1200 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 3, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:   Machine shop  - On or about 6/27/2013, the employer did not have a material safety data sheet for Kool Mist.
Recent events (1)
  • · Z (S) $0

View U.S. Coast Guard Industrial Product Detachment (IPD)'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339271876.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.