SONORA, CA ·
OSHA Inspection: U.S. DEPT. OF AGRICULTURE - FOREST SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. DEPT. OF AGRICULTURE - FOREST SERVICE in STANISLAUS NATIONAL FOREST 19777 GREENLEY ROAD, SONORA, CA 95370 (NAICS 115310). OSHA activity number 339157273.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. DEPT. OF AGRICULTURE - FOREST SERVICE
- Site address
- STANISLAUS NATIONAL FOREST 19777 GREENLEY ROAD
- City
- SONORA
- State
- CA
- ZIP
- 95370
- Mailing
- 19777 GREENLEY ROAD, SONORA, CA 95370
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115310
- Employees
- 100
- Ownership type
- Federal government (D)
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Oct 23, 2013
- Abate by
- Dec 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard: Noted on or about 6/26/13 and at times prior thereto, the following storage platforms were deficient in the following ways: Vehicle Maintenance Shop - Two storage platforms, one above the office and the "Smokey" storage platform, were not equipped with standard guard rails that include top and mid-rails and toe boards. Employee's are potentially exposed to a measured fall hazard height of 8 feet, 8 inches. Employees pass by and work in the areas below the storage platforms and materials are stored near the edge. Warehouse - The storage platform did not have a section of railing replaced after the area was accessed. Employees are potentially exposed to a measured fall hazard of 7 feet, 5 inches. Materials are stored on the edge of the platform and an employee works in the area below the platform.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.106 E09 III
- Issued
- Oct 23, 2013
- Abate by
- Oct 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) Vehicle Maintenance Shop - Noted on or about 6/26/13 and at times prior thereto, rags soaked with flammable lacquer thinner were hung outside to dry before placing them in an approved safety can.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Oct 23, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Vehicile Maintenance Shop and Carpentry Shop - Noted on or about 6/26/13 and at times prior thereto, a Craftsman 20 " drill press (Vehicle Maintenance) and a Delta 8" drill press (Carpentry) did not have guards at the point of operation.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G01
- Issued
- Oct 23, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Warehouse - Noted on or about 6/26/13 and at times prior thereto, the panel board (120-240V) was blocked by boxes and did not permit a 3-foot minimum clearance.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.22 A01
- Issued
- Oct 23, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a) Warehouse, ground level and storage platform - Noted on or about 6/26/13 and at times prior thereto, the aisles are blocked by boxes and do not allow safe passage
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at U.S. Dept. of Agriculture - Forest Service
View U.S. Dept. of Agriculture - Forest Service's full OSHA safety record →
More inspections in this industry (NAICS 115310)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339157273.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.